2007
DOI: 10.1080/09537100701280654
|View full text |Cite
|
Sign up to set email alerts
|

Clopidogrel anti-platelet effect: An evaluation by optical aggregometry, impedance aggregometry, and the Platelet Function Analyzer (PFA-100™)

Abstract: Platelet aggregation inhibition by clopidogrel may be suboptimal in 4-30% of patients. Traditionally, optical aggregometry is used to assess clopidogrel's anti-platelet effects by inhibition of ADP-induced aggregation in platelet rich plasma. Red blood cells are an important source of ADP and, thus, are known to modulate platelet function. Because the whole blood aggregation by impedance method assesses platelet function in a physiological milieu, we compared clopidogrel response by this method with the optica… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
56
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 50 publications
(57 citation statements)
references
References 41 publications
1
56
0
Order By: Relevance
“…Their result was in concordance with other studies [24,25] . The broad use of statins, angiotensin receptor blockers and selective serotonin reuptake inhibitors may be, in part, responsible for the lack of agreement [26] .…”
supporting
confidence: 83%
“…Their result was in concordance with other studies [24,25] . The broad use of statins, angiotensin receptor blockers and selective serotonin reuptake inhibitors may be, in part, responsible for the lack of agreement [26] .…”
supporting
confidence: 83%
“…In particular, AR-C66096 inhibited aggregations to collagen at all concentrations tested in 96-well aggregometry, but only at the lowest collagen concentration in LTA. Similarly, it has been previously shown that clopidogrel has greater effects upon collagen-induced aggregation measured in 96-well aggregometry than in LTA (8,9). We can speculate that differences in the volume of PRP and the presence or not of a stir bar play a critical role in determining fluid dynamics within the sample and the formation of aggregates dependent upon secondary mediators.…”
Section: Discussionmentioning
confidence: 58%
“…Posteriorly, the need to evaluate platelet function led to the development of technologies such as the PFA-100, a precise, convenient and reliable method that assesses platelet function globally and automatically in citrated whole blood (8,9). However, this system does not detect the effect of certain antiplatelet drugs upon platelet function (10)(11)(12). A recent introduction on the market has been the mentioned Multiplate System® analyzer, which uses different tests to generate reliable information on platelet function and on the effects of antiplatelet treatment.…”
Section: Discussionmentioning
confidence: 99%