2016
DOI: 10.5194/isprs-archives-xli-b5-115-2016
|View full text |Cite
|
Sign up to set email alerts
|

Close Range Calibration of Long Focal Length Lenses in a Changing Environment

Abstract: ABSTRACT:University College London is currently developing a large-scale multi-camera system for dimensional control tasks in manufacturing, including part machining, assembly and tracking, as part of the Light Controlled Factory project funded by the UK Engineering and Physical Science Research Council. In parallel, as part of the EU LUMINAR project funded by the European Association of National Metrology Institutes, refraction models of the atmosphere in factory environments are being developed with the inte… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…The temperature in the production hall can vary, and the temperature amplitude in a day–night cycle can also be very high. Taking into account the differences in environmental conditions, temperature is one of the most important factors that needs to be taken into account when considering the accuracy of measurements performed with any camera-based system [ 5 , 9 , 12 , 13 , 17 , 18 , 19 , 20 , 21 ]. The solution of this issue can be either software or hardware.…”
Section: Introductionmentioning
confidence: 99%
“…The temperature in the production hall can vary, and the temperature amplitude in a day–night cycle can also be very high. Taking into account the differences in environmental conditions, temperature is one of the most important factors that needs to be taken into account when considering the accuracy of measurements performed with any camera-based system [ 5 , 9 , 12 , 13 , 17 , 18 , 19 , 20 , 21 ]. The solution of this issue can be either software or hardware.…”
Section: Introductionmentioning
confidence: 99%
“…(Liang et al, 2014) propose a robust algorithm to calibrate the camera with a long focal length without using additional devices by adding a regularization term to computational process. (Robson et al, 2016) represents results of long focal length camera calibration in Violet and IR light. Figure 2.…”
Section: Introductionmentioning
confidence: 99%
“…The recently completed international collaboration on the project "Large volume unified metrology for industry and novel applications and research (LUMINAR)" [6] focused on the refractive index effects in an industrial setting. They found that in a typical aircraft industrial space the positional measurement uncertainty can be significant [7]. In addition, [8] found that a light beam will deviate from a straight line by 0.2 mm for every 15 m it travels horizontally when there is a vertical temperature gradient of approximately 2 K/m (and a vertical height of 6m).…”
Section: Introductionmentioning
confidence: 99%