2022
DOI: 10.1039/d2nj00596d
|View full text |Cite
|
Sign up to set email alerts
|

CO2 uptake prediction of metal–organic frameworks using quasi-SMILES and Monte Carlo optimization

Abstract: Metal-organic frameworks (MOFs) are organic-inorganic hybrid crystalline porous with high specific surface areas that have revolutionized materials science and adsorbent development. The research aims to investigate and develop QSPR (quantitative...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
3

Relationship

2
6

Authors

Journals

citations
Cited by 13 publications
(13 citation statements)
references
References 100 publications
0
13
0
Order By: Relevance
“…The mathematical equations of the applied statistical criteria are very well explained in the literature. 32,37 All designed QSAR models were statistically reliable and the numerical values of statistical quantities were found in acceptable ranges as reported in the literature. 33,34 In QSTR modelling of pEC 1).…”
Section: Model Validationmentioning
confidence: 58%
See 1 more Smart Citation
“…The mathematical equations of the applied statistical criteria are very well explained in the literature. 32,37 All designed QSAR models were statistically reliable and the numerical values of statistical quantities were found in acceptable ranges as reported in the literature. 33,34 In QSTR modelling of pEC 1).…”
Section: Model Validationmentioning
confidence: 58%
“…The balance of the correlation method was used to compute TF1 whereas the IIC was added to the TF 1 to attain the modified target function TF 2 . 32 TF 1 = R TRN + R ITRN − | R TRN − R ITRN | × 0.1 TF 2 = TF 1 + IIC CAL × C Here, R TRN and R ITRN are the correlation coefficients for the training and invisible training sets, respectively. The C is an empirical coefficient or weight of IIC, here C = 0.2.…”
Section: Methodsmentioning
confidence: 99%
“…According to the published methodology we classified the obtained SA K s as promoters of the corneal permeability increase or decrease. [19][20][21][34][35][36] In Table 4 we enlist selected SA K s with their mechanistic interpretation while the complete list is given in Table S2 (ESI †). We present the analysis of molecular fragments' contribution to corneal permeability in Fig.…”
Section: Resultsmentioning
confidence: 99%
“…The SMILES notations, split distribution, experimental pIC 50 , predicted pIC 50, and applicability domain of each compound are depicted in Table S1. The task of each set in developing the QSAR models was already described in the literature 31,32 .…”
Section: Methodsmentioning
confidence: 99%
“…In the present research modified target function (TF m ) i.e. the balance of correlation with IIC was employed to compute the DCW 32 . The following mathematical relationships are used to compute TF m : (3) The index of ideality if correlation for the calibration set (IIC CAL ) is calculated using the following equation:…”
Section: Monte Carlo Optimizationmentioning
confidence: 99%