2018
DOI: 10.1364/oe.26.031542
|View full text |Cite
|
Sign up to set email alerts
|

Coherent beam combining of seven fiber chirped-pulse amplifiers using an interferometric phase measurement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 22 publications
(15 citation statements)
references
References 13 publications
0
15
0
Order By: Relevance
“…This detection method has been demonstrated to be theoretically scalable up to about 10,000 fibers [3]. First proof of principles of the XCAN project have been published with 19 passive fibers and 7 high power fiber amplifiers [4,5]. In this paper, we report on the CBC of 37 fiber amplifiers in the femtosecond regime in the way towards our goal of 61 channels.…”
Section: Coherent Beam Combining Of 37 Femtosecond Fiber Amplifiersmentioning
confidence: 99%
“…This detection method has been demonstrated to be theoretically scalable up to about 10,000 fibers [3]. First proof of principles of the XCAN project have been published with 19 passive fibers and 7 high power fiber amplifiers [4,5]. In this paper, we report on the CBC of 37 fiber amplifiers in the femtosecond regime in the way towards our goal of 61 channels.…”
Section: Coherent Beam Combining Of 37 Femtosecond Fiber Amplifiersmentioning
confidence: 99%
“…with the same accuracy. This method does not provide topographic details; however, this is not a problem in the context of intense lasers obtained by recombination of fiber lasers because it is known that the defects to be measured are limited to pistons and tilts [1][2][3], or in specific cophasing issues [4]. Moreover, the technique does not need a local reference at the time of measurement, which leads to decoupling between calibration step and measurement step.…”
Section: Comparison With the Psi Measurements And Discussionmentioning
confidence: 99%
“…Today, there exists a large panel of projects relying on segmented wavefronts tailoring, either in coherent combination of elementary fiber lasers [1][2][3], astronomy [4], or ophthalmology [5].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The Digital-to-Analog Converter (DAC) addressing the FS currently limits the accuracy at about ± /50. This value does not compete with state of the art SLMs ( /10000) [13] but is more than sufficient regarding CBC requirements [14]. A couple orders of magnitude improvement could nevertheless be achieved by adjusting DAC current voltage accuracy from current ±10 mV down to sub mV precision while taking adequate electromagnetic environment noise isolation.…”
Section: Fig 2 Near Field Interference Pattern Of 61 Beamlets As Opmentioning
confidence: 99%