2022
DOI: 10.3389/fvets.2022.908829
|View full text |Cite
|
Sign up to set email alerts
|

Color M-Mode Echocardiography for Non-Invasive Assessment of the Intraventricular Pressure in Dogs Before and After Ductus Arteriosus Occlusion: A Retrospective Study

Abstract: BackgroundNovel non-invasive evaluation of the intraventricular pressure differences and gradients (IVPD and IVPG) by color M-mode echocardiography (CMME) is a promising method in diastolic function evaluation. Patent ductus arteriosus (PDA) is a congenital heart defect which is associated with increased preload. The present work provides a clinical trial for the assessment of IVPD and IVPG changes in dogs before and after surgical occlusion of PDA.Materials and MethodsA total of 12 client-owned dogs were enro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 5 publications
(9 citation statements)
references
References 40 publications
1
4
0
Order By: Relevance
“…Our results demonstrated varying significant correlations and regressions among the IVPG, HRV, and conventional echocardiographic parameters. Specifically, our findings regarding IVPG were consistent with previously reported results in rats, dogs, and goats ( 33 , 98 , 99 ), which also showed varying correlations between heart function parameters and IVPG variables. Furthermore, we observed a significant correlation and regression between HRV measurement and heart function parameters ( 100 , 101 ).…”
Section: Discussionsupporting
confidence: 92%
“…Our results demonstrated varying significant correlations and regressions among the IVPG, HRV, and conventional echocardiographic parameters. Specifically, our findings regarding IVPG were consistent with previously reported results in rats, dogs, and goats ( 33 , 98 , 99 ), which also showed varying correlations between heart function parameters and IVPG variables. Furthermore, we observed a significant correlation and regression between HRV measurement and heart function parameters ( 100 , 101 ).…”
Section: Discussionsupporting
confidence: 92%
“…These results are quite reasonable particularly when we consider that these data were calculated before sedation. The higher CV of apical indices may be related to variation in the color resolution of the apical part of CMME images compared with the basal and mid parts ( 7 ). Therefore, CMME can be used for further evaluation of heart function in goats and the apical variables should be considered with caution.…”
Section: Discussionmentioning
confidence: 99%
“…After CMME image acquisition, the IVPD was calculated using in-house code written in MATLAB (The MathWorks, Natick, MA, USA). In each goat, by using the conventional echocardiography images and the displayed ECG, the time from aortic opening to aortic closure (aortic flow images) and the time from Q wave on ECG to the start of mitral valve opening as well as the time from Q wave to peak mitral inflow (mitral inflow images) were obtained and manually inserted into the software during each photo processing by MATLAB ( 7 ). Automatic and manual correction of the resulting curves using specific software codes was applied when required to enhance the quality of analysis.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations