2012
DOI: 10.1016/j.foodchem.2011.07.010
|View full text |Cite
|
Sign up to set email alerts
|

Colour and phenolic compounds in sweet red wines from Merlot and Tempranillo grapes chamber-dried under controlled conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
49
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 55 publications
(54 citation statements)
references
References 38 publications
5
49
0
Order By: Relevance
“…A volume of 50 L of the sample was injected into an HPLC-DAD instrument (Beckman Coulter System Gold, 168 Detector) and the analyses were carried out on a LiChrospher 100 RP-18 column (250 mm × 4.6 mm, 5 m), according to the method proposed by Marquez et al [23]. The identification was carried out by comparing their retention times with those for standards, recording UV-Vis spectra, and calculating the UV absorbance ratios for samples and standards simultaneously coinjected one at a time.…”
Section: Identification and Quantification Of Flavonols By Hplc-dadmentioning
confidence: 99%
“…A volume of 50 L of the sample was injected into an HPLC-DAD instrument (Beckman Coulter System Gold, 168 Detector) and the analyses were carried out on a LiChrospher 100 RP-18 column (250 mm × 4.6 mm, 5 m), according to the method proposed by Marquez et al [23]. The identification was carried out by comparing their retention times with those for standards, recording UV-Vis spectra, and calculating the UV absorbance ratios for samples and standards simultaneously coinjected one at a time.…”
Section: Identification and Quantification Of Flavonols By Hplc-dadmentioning
confidence: 99%
“…For the extraction and fractionation of anthocyanins, the method proposed by Marquez et al (2012b) was used. A volume of 2 mL of wine was passed through a Sep-Pak C18 cartridge packed with 900 mg of material (Long Body Sep-Pak Plus, Water Associates, Milford, MA) that was previously activated with 5 mL of methanol and washed with aqueous 0.01% (v/v) HCl.…”
Section: Analysis Of Phenolic Compoundsmentioning
confidence: 99%
“…Other phenolic compounds were extracted with a combination of two cartridges to ensure effective separation (Marquez et al, 2012b). Thus, a volume of 15 mL of wine was adjusted to pH 7 with 0.1 M NaOH and passed through Sep-Pak C18 cartridges previously activated with 5 mL of methanol and washed with distilled water, which was adjusted to pH 7 with NaOH.…”
Section: Analysis Of Phenolic Compoundsmentioning
confidence: 99%
See 2 more Smart Citations