2021
DOI: 10.1021/acs.analchem.1c02036
|View full text |Cite
|
Sign up to set email alerts
|

Combination of Exhaled Breath Analysis with Parallel Lung Function and FeNO Measurements in Infants

Abstract: Breath analysis by secondary electrospray ionization-high resolution mass spectrometry (SESI-HRMS) offers the possibility to measure comprehensive metabolic profiles. The technology is currently being deployed in several clinical settings in Switzerland and China. However, patients are required to exhale directly into the device located in a dedicated room. Consequently, clinical implementation in patients incapable of performing necessary exhalation maneuvers (e.g., infants) or immobile (e.g., too weak, elder… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
29
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(29 citation statements)
references
References 24 publications
0
29
0
Order By: Relevance
“…All samples were collected and analyzed in the same room. The exhaled breath collection was carried out by means of the off-line device described by Decrue et al [30], which consists of a Nalophan® bag of approximately 2 l volume and 700 cm 2 surface (Nalophan® NA, 20 ± 5 µm thick, Kalle) coupled at one end to a mouthpiece (Hudson RCI®) and at the other end to a tube (Rotilabo® PTFE, 6 mm, 8 mm, length 90 mm, Carl Roth®) connected to a valve (VHK2-08F-08F, SMC Switzerland). The Nalophan® bags were prepared the day before the visit of the subjects.…”
Section: Study Participants and Breath Samplingmentioning
confidence: 99%
See 4 more Smart Citations
“…All samples were collected and analyzed in the same room. The exhaled breath collection was carried out by means of the off-line device described by Decrue et al [30], which consists of a Nalophan® bag of approximately 2 l volume and 700 cm 2 surface (Nalophan® NA, 20 ± 5 µm thick, Kalle) coupled at one end to a mouthpiece (Hudson RCI®) and at the other end to a tube (Rotilabo® PTFE, 6 mm, 8 mm, length 90 mm, Carl Roth®) connected to a valve (VHK2-08F-08F, SMC Switzerland). The Nalophan® bags were prepared the day before the visit of the subjects.…”
Section: Study Participants and Breath Samplingmentioning
confidence: 99%
“…Exhaled breath samples were analyzed using a SESI ion source (SuperSESI, FIT, Spain) coupled to a high resolution mass spectrometer (Q-Exactive Plus, Thermo Fisher Scientific, Germany) following the protocol described above [27,30,36]. Once the storage period had been completed, the exhaled breath contained in the Nalophan® bags was infused into the ion source.…”
Section: Breath Analysismentioning
confidence: 99%
See 3 more Smart Citations