1980
DOI: 10.1021/ac50064a011
|View full text |Cite
|
Sign up to set email alerts
|

Combined capillary gas chromatography/atmospheric pressure negative chemical ionization/mass spectrometry for the determination of 2,3,7,8-tetrachlorodibenzo-p-dioxin in tissue

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
39
0

Year Published

1980
1980
2015
2015

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 96 publications
(40 citation statements)
references
References 18 publications
1
39
0
Order By: Relevance
“…However, several studies of Ni-APCI have shown this method to have excellent sensitivity, especially for compounds with positive electron affinity (EA) [5,12,13]. Early work with APCI was primarily carried out using gas chromatographic introduction and, thus, the ion source was solvent free [13][14][15][16][17]. In particular, GC/APMS operated in the negative ion mode was demonstrated to be a highly sensitive method for detecting a number of environmentally important compounds [14,18].…”
Section: Resultsmentioning
confidence: 99%
“…However, several studies of Ni-APCI have shown this method to have excellent sensitivity, especially for compounds with positive electron affinity (EA) [5,12,13]. Early work with APCI was primarily carried out using gas chromatographic introduction and, thus, the ion source was solvent free [13][14][15][16][17]. In particular, GC/APMS operated in the negative ion mode was demonstrated to be a highly sensitive method for detecting a number of environmentally important compounds [14,18].…”
Section: Resultsmentioning
confidence: 99%
“…The abundance of these negative ions is a function of both the ion source temperature and the concentration of O 2 in the nitrogen buffer gas [20,38], as shown in eq. The applied cone voltage affects the ionization/fragmentation.…”
Section: A N U S C R I P Tmentioning
confidence: 99%
“…However, in the case of APCI, chemical equilibrium conditions can be attained, contrary to other ionization modes performed only under lowered pressures and non-equilibrium conditions. The main ion-molecule reactions in APCI, as for NCI with oxygen as reagent gas, are described as follows: The molecular ion for 2,3,7,8-TCDD cannot be obtained under APCI conditions with oxygen as reagent gas (Mitchum, Moler, & Korfmacher, 1980;Clement & Tosine, 1988). The detection limits for 2,3,7,8-TCDD/F in the SIM mode were 0.5 pg for the 2,3,7,8-TCDF standard (Clement & Tosine, 1988) and 14-40 pg in deionized water .…”
Section: B Sensitive Detection: Negative Chemical Ionization With DImentioning
confidence: 99%