2015
DOI: 10.1517/17425247.2015.1074174
|View full text |Cite
|
Sign up to set email alerts
|

Combining glucose monitoring and insulin delivery into a single device: current progress and ongoing challenges of the artificial pancreas

Abstract: Despite the widespread availability of insulin pumps, continuous glucose sensors, and insulin analogs with rapid-acting pharmacokinetic profiles, most people with type 1 diabetes fail to meet recommended glycemic targets, rates of severe hypoglycemia remain unacceptably high, and the burden of care on patients and loved ones exacts an enormous psychosocial toll. The combination of continuous glucose monitoring with insulin delivery into an integrated automated system promises to improve diabetes control while … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

2017
2017
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 14 publications
0
3
0
1
Order By: Relevance
“…As patients become familiar with the AP’s capabilities and limitations, and as they witness its performance and reliability, they will develop trust in the technology in partly controlling their T1D. Yet, technical problems (e.g., issues with the equipment or software) or limitations of current AP versions (e.g., imprecise glucose sensor readings in hypoglycaemic or hyperglycaemic peaks or due to inappropriate calibration [28, 30, 72]) could diminish users’ trust in the technology.…”
Section: Domains Of Ethical Issuesmentioning
confidence: 99%
See 1 more Smart Citation
“…As patients become familiar with the AP’s capabilities and limitations, and as they witness its performance and reliability, they will develop trust in the technology in partly controlling their T1D. Yet, technical problems (e.g., issues with the equipment or software) or limitations of current AP versions (e.g., imprecise glucose sensor readings in hypoglycaemic or hyperglycaemic peaks or due to inappropriate calibration [28, 30, 72]) could diminish users’ trust in the technology.…”
Section: Domains Of Ethical Issuesmentioning
confidence: 99%
“…Despite making T1D management more discrete, the AP still contributes to the visibility of the illness by being a cumbersome and an uncomfortable external system for some patients [30, 77]. The insulin pump and the catheter can impose restrictions or adjustments on clothing and are also problematic for intimate relationships [78].…”
Section: Domains Of Ethical Issuesmentioning
confidence: 99%
“…Aunque su nombre sugiere la creación de un páncreas por ingeniería, este tipo de tratamiento dista de ser un páncreas igual al humano [15][16] . El paciente debe cambiar el set de infusión y el sensor de glicemia periódicamente y también debe informar al equipo de la ingesta de comida.…”
Section: Páncreas Artificial (Pa) Y Sistema Híbridounclassified
“…More sophisticated controller algorithms, such as proportional–integral–derivative (PID) control, model predictive control, fuzzy logic (FL) control, and adaptive control algorithms have been developed and extensively evaluated for insulin delivery in AP systems [ 14 , 15 ].…”
Section: Introductionmentioning
confidence: 99%