2015 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC) 2015
DOI: 10.1109/appeec.2015.7380917
|View full text |Cite
|
Sign up to set email alerts
|

Communication architecture and data acquisition for experimental MicroGrid installations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
22
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
4
2
1

Relationship

3
4

Authors

Journals

citations
Cited by 26 publications
(22 citation statements)
references
References 5 publications
0
22
0
Order By: Relevance
“…Three commercial buildings are considered as the loads for the MGs to test the proposed system. The PV and commercial building load data is extracted from Griffith University monitoring system [19]. The representation of the LV network is depicted in Figure 11.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Three commercial buildings are considered as the loads for the MGs to test the proposed system. The PV and commercial building load data is extracted from Griffith University monitoring system [19]. The representation of the LV network is depicted in Figure 11.…”
Section: Resultsmentioning
confidence: 99%
“…The VSIs are connected to the grid via an LCL filter and an L filter in the fourth leg to remove the harmonics. The commercial buildings are modelled as singlephase R-L combinations, where the actual data of load consumption of MGs, taken from the university monitoring system [19], is employed to model the MMG loads. The VSI is modelled to provide stable DC and AC side voltage and current.…”
Section: System Descriptionmentioning
confidence: 99%
See 1 more Smart Citation
“…Modbus TCP/IP (Transmission Control Protocol/Internet Protocol) has been used as the communication protocol for supervisory control and data acquisition (SCADA) systems. Hypertext Transfer Protocol (HTTP) TCP/IP communication protocol has been used as the backup protocol when the Modbus TCP/IP is not available [26]. MGCC is responsible for generating command signals for the LCs.…”
Section: Hybrid Ac/dc Microgridmentioning
confidence: 99%
“…Wireless communication infrastructure like WIFI or ZigBee has a slower data transmission rate and affected by interference. However, it has many advantages including easy, fast, and low-cost instalment and perfectly fits the needed high flexibility option (plug-and-play) of MGs with a large number of DGs and loads [5].…”
Section: Introductionmentioning