Background
The incidence of typhoid fever is increasing in Egypt. The Widal test is the evaluation most widely used in Egypt for diagnosis, but it has many drawbacks; therefore, new diagnostic tools are needed. Our aim was to evaluate the diagnostic accuracy of the onsite typhoid IgG/IgM combo rapid test in diagnosing typhoid fever.
Method
Blood specimens were collected from 90 patients (of all ages) who presented with fever of more than 4 days’ duration. The OnSite Combo test and the Widal test were performed for all patients.
Results
The OnSite Combo test results were positive in approximately 24% of all patients; the Widal test results were positive in 18.9%; and typhoid was diagnosed through blood culture in 32.2%. The OnSite Combo test had 72.4% sensitivity, 98.4% specificity, a positive predictive value of 95.5%, and a negative predictive value of 88.2%. In contrast, the Widal test had 51.7% sensitivity, 69.7% specificity, a positive predictive value of 88.2%, and a negative predictive value of 80.8%.
Conclusions
The onsite combo test was more efficacious than the Widal test in diagnosing typhoid fever.