Comparative analysis of heat loss performance of flat plate solar collectors at different altitudes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 24 publications
0
5
0
Order By: Relevance
“…However, there was not enough information provided about the modelling approach. 15 In addition, a similar study on the flat plate collector has already been covered way before in Dhaundiyal and Gabrielmichael's work. 6 Zheng et al examined the solar heating cooling system integrated with a parabolic trough collector (PTC).…”
Section: Introductionmentioning
confidence: 85%
See 2 more Smart Citations
“…However, there was not enough information provided about the modelling approach. 15 In addition, a similar study on the flat plate collector has already been covered way before in Dhaundiyal and Gabrielmichael's work. 6 Zheng et al examined the solar heating cooling system integrated with a parabolic trough collector (PTC).…”
Section: Introductionmentioning
confidence: 85%
“…22 Singh et al provided valuable insight into the recent development in the artificial roughened surface of the absorber plate, the flow pattern of the medium, and the scope of multi-passes in the solar air collector. 23 After reviewing, [3][4][5][6][7][8][9][10][11][12][13][14][15][16][17][18] it was seen that the mathematical models are the energy equations that are solved using the computation software. A new approach was not seen except in the study by Gopi et al 17 In this article, a unique approach was adopted that is based on nonlinear system identification without using rudimentary algebra or statistical models.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Ma et al [9] set the lower dead zone of the switch control strategy and the temperature difference of the continuous control strategy for PV/T to improve system performance. Liu et al [10] divided the operating modes of solar heat pumps coupled with wind energy storage heating systems into three types in order to adjust to environmental disturbances and fluctuations and achieve flexible operation.…”
Section: Introductionmentioning
confidence: 99%
“…Subiantoro and Ooi [4] developed analytical methods for the calculation of the heat losses from the top of the collector. Wang et al [5] performed a comparative analysis of the convection and radiation heat losses on the surface of FPC for different altitudes and studied the effects of the environmental conditions such as air pressure and density. He et al [6] conducted an experimental analysis on the effect of nanofluids on flat plate collectors' efficiencies and calculated the optimum concentration of nanofluids.…”
Section: Introductionmentioning