2015
DOI: 10.1016/j.ijcard.2015.01.086
|View full text |Cite
|
Sign up to set email alerts
|

Comparative assessment of ascending aortic aneurysms in Marfan patients using ECG-gated computerized tomographic angiography versus trans-thoracic echocardiography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0
3

Year Published

2018
2018
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 24 publications
(12 citation statements)
references
References 21 publications
0
9
0
3
Order By: Relevance
“…Expectedly, the difference between echocardiographic leading-edge diameter and MRA-derived outer diameters (~ 7 mm) was higher and clinically more relevant than the difference from MRA-derived inner diameters (~ 1 mm). The remaining small difference between MRA-derived inner-to-inner diameters and echocardiographic leading-edge diameters is explained by the different angle of incidence and imaging modalities [31]. Taken together, MRA-derived inner-to-inner measurements show a smaller variance and higher agreement with echocardiographic measurements than outer-to-outer measurements.…”
Section: Discussionmentioning
confidence: 86%
“…Expectedly, the difference between echocardiographic leading-edge diameter and MRA-derived outer diameters (~ 7 mm) was higher and clinically more relevant than the difference from MRA-derived inner diameters (~ 1 mm). The remaining small difference between MRA-derived inner-to-inner diameters and echocardiographic leading-edge diameters is explained by the different angle of incidence and imaging modalities [31]. Taken together, MRA-derived inner-to-inner measurements show a smaller variance and higher agreement with echocardiographic measurements than outer-to-outer measurements.…”
Section: Discussionmentioning
confidence: 86%
“…Deben registrarse los diámetros a nivel del anillo, senos de Valsalva, unión senotubular, aorta ascendente tubular y arco aórtico. El diámetro máximo de la raíz debe tomarse de seno a seno, en lugar del diámetro máximo de seno a comisura, ya que esta medida se correlaciona mejor con los diámetros máxi-mos en el plano largo de borde exterior a borde exterior medidos por ecocardiografía 54,55 . Véase la tabla de recomendaciones sobre las indicaciones de cirugía en la insuficiencia aórtica grave y en la enfermedad de la raíz aórtica para su definición.…”
Section: Tomografía Computarizada Y Resonancia Magnética Cardiacaunclassified
“…Despite the relatively small population size, we were able to detect statistically significant differences in tortuosity values both in the case-control comparison and in the analysis of severity groups, which underscores the robustness of the applied tortuosity metrics. Furthermore, our study population is comparable in size to previous human MFS studies [34,35].…”
Section: Limitationsmentioning
confidence: 60%