2021
DOI: 10.1186/s12872-021-02061-y
|View full text |Cite
|
Sign up to set email alerts
|

Comparative efficacy of image-guided techniques in cardiac resynchronization therapy: a meta-analysis

Abstract: Background Several studies have illustrated the use of echocardiography, magnetic resonance imaging, and nuclear imaging to optimize left ventricular (LV) lead placement to enhance the response of cardiac resynchronization therapy (CRT) in heart failure patients. We aimed to conduct a meta-analysis to determine the incremental efficacy of image-guided CRT over standard CRT. Methods We searched PubMed, Cochrane library, and EMBASE to identify releva… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0
2

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(14 citation statements)
references
References 37 publications
0
12
0
2
Order By: Relevance
“…A recently published meta-analysis by Hu et al, was limited to evaluating only image-guidance and included both randomised and non-randomised studies. This was limited by heterogenous study designs and excluded non-image-based guidance techniques 7 . A network meta-analysis (NMA) was deemed appropriate to allow comparative assessment of different guidance modalities and potentially direct clinicians to which guidance modalities derived most benefit for patients.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…A recently published meta-analysis by Hu et al, was limited to evaluating only image-guidance and included both randomised and non-randomised studies. This was limited by heterogenous study designs and excluded non-image-based guidance techniques 7 . A network meta-analysis (NMA) was deemed appropriate to allow comparative assessment of different guidance modalities and potentially direct clinicians to which guidance modalities derived most benefit for patients.…”
Section: Introductionmentioning
confidence: 99%
“… 4 The targeting of the optimal LV lead position through a variety of guidance techniques has been investigated; however, with the increasing use of image-fusion technology 5 and number of randomized trials being undertaken with more advanced imaging techniques, 6 the need for an updated evaluation of the data is needed. A recently published meta-analysis by Hu and colleagues 7 was limited to evaluating only image guidance and included both randomized and nonrandomized studies. This was limited by heterogenous study designs and excluded non-image-based guidance techniques.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Previous meta-analyses and RCTs showed no clinical improvement with imaging-guided optimization compared with usual care, including fixed intervals or hemodynamic optimization. 26 , 27 , 28 , 29 , 30 Ultimately, the response to CRT may be dictated in large part by patient selection and multipoint lead positioning, leaving little to be gained in AV and VV interval titration compared to fixed settings. 31 , 32 , 33 …”
Section: Discussionmentioning
confidence: 99%
“…Placement of left ventricular (LV) pacing leads at sites of latest activation in viable myocardium provides better cardiac resynchronization therapy (CRT) response. Hu et al 106 investigated the incremental efficacy of image-guided CRT over standard CRT in 1075 patients from 8 studies, of which 544 patients underwent image-guided CRT implantation and 531 underwent routine implantation without imaging guidance. Comparing the routine group, the improvement in LV ejection fraction is significantly higher in the image-guided group (weighted mean difference: 3.25, 95% CI: 1.80-4.70, P < 0.01) with no significant difference in hospitalization (RR: 0.89, 95% CI: 0.16-5.08, P = 0.90) or mortality (RR: 0.69, 95% CI: 0.37-1.29, P = 0.24).…”
Section: Imaging In Cardiomyopathymentioning
confidence: 99%