2016
DOI: 10.1016/j.energy.2016.08.050
|View full text |Cite
|
Sign up to set email alerts
|

Comparative evaluation of R1234yf, R1234ze(E) and R450A as alternatives to R134a in a variable speed reciprocating compressor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
20
0
2

Year Published

2018
2018
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 62 publications
(23 citation statements)
references
References 24 publications
1
20
0
2
Order By: Relevance
“…The R448A has a higher cooling capacity (Qe) than the R404A as it is composed of the hydrofluorocarbons (HFCs) R32 [6,21,23] and has a lower global warming potential (GWP) than the R404A, which is composed of hydrofluoroolefins (HFOs) by R1234yf and R1234ze (E) [24][25]. The result show a decrease in the global warming potential by 70%, and a COP higher than R404A [26], as shown in Figure 7 [27].…”
Section: R448a Refrigerantmentioning
confidence: 98%
“…The R448A has a higher cooling capacity (Qe) than the R404A as it is composed of the hydrofluorocarbons (HFCs) R32 [6,21,23] and has a lower global warming potential (GWP) than the R404A, which is composed of hydrofluoroolefins (HFOs) by R1234yf and R1234ze (E) [24][25]. The result show a decrease in the global warming potential by 70%, and a COP higher than R404A [26], as shown in Figure 7 [27].…”
Section: R448a Refrigerantmentioning
confidence: 98%
“…If instead a replacement fluid for a given existing system is needed then things change because e.g., it can no longer be assumed that the compressor will work equally well with any fluid. Similar approaches are seen in experimental studies which investigate the general suitability and efficiency of different fluids in a laboratory scale test-rig [6,[11][12][13] or in single components like compressors or heat exchangers [14][15][16]. These investigations often lead to interesting heuristics, but they are not very helpful in finding replacement fluids for a concrete plant since the COP, heat flow rates and compressor power of another concrete system will have with a different fluid cannot be estimated.…”
Section: Introductionmentioning
confidence: 93%
“…The R448A has a higher cooling capacity (Qe) than the R404A as it is composed of the hydrofluorocarbons (HFCs) R32 [5,18,20]. And it has a lower global warming potential (GWP) than the R404A, which is composed of hydrofluoroolefins (HFOs) by R1234yf and R1234ze (E) [21,22]. The result shows a decrease in the global warming potential by 70%, and a COP higher than R404A as shown in Figure 7 [11,23].…”
Section: Evolution Of the Refrigerantmentioning
confidence: 99%