2020
DOI: 10.1186/s12936-020-03379-2
|View full text |Cite
|
Sign up to set email alerts
|

Comparative evaluation of two commercial real-time PCR kits (QuantiFast™ and abTES™) for the detection of Plasmodium knowlesi and other Plasmodium species in Sabah, Malaysia

Abstract: Background: The monkey parasite Plasmodium knowlesi is an emerging public health issue in Southeast Asia. In Sabah, Malaysia, P. knowlesi is now the dominant cause of human malaria. Molecular detection methods for P. knowlesi are essential for accurate diagnosis and in monitoring progress towards malaria elimination of other Plasmodium species. However, recent commercially available PCR malaria kits have unpublished P. knowlesi gene targets or have not been evaluated against clinical samples. Methods: Two real… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
2
1

Relationship

3
5

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 43 publications
0
10
0
Order By: Relevance
“…The major problem is often observed for detection of simian malaria Pk that also causes infection in human. Besides, the commercial kit available to detect Pk often shows false positive result in mixed infection at low parasitemia with a LOD of 0.125 and 20 parasites/µL only [ 41 ]. Targeting high copy telomere associated repetitive element and var gene acidic terminal achieved a LOD of 0.03 to 0.15 parasites/µL for detection of Pf [ 42 ] while 18s rRNA target based approach in clinical isolates resulted in detection of Pf and Pv wih LOD of 1–10 parasites/µL with 100% sensitivity [ 43 ].…”
Section: Discussionmentioning
confidence: 99%
“…The major problem is often observed for detection of simian malaria Pk that also causes infection in human. Besides, the commercial kit available to detect Pk often shows false positive result in mixed infection at low parasitemia with a LOD of 0.125 and 20 parasites/µL only [ 41 ]. Targeting high copy telomere associated repetitive element and var gene acidic terminal achieved a LOD of 0.03 to 0.15 parasites/µL for detection of Pf [ 42 ] while 18s rRNA target based approach in clinical isolates resulted in detection of Pf and Pv wih LOD of 1–10 parasites/µL with 100% sensitivity [ 43 ].…”
Section: Discussionmentioning
confidence: 99%
“… 37 , 38 Patients who were not confirmed by PCR to have P. knowlesi monoinfection were retrospectively excluded, using a validated PCR assay. 58 In contrast to the ACTKNOW study, only one participant was excluded due to P. vivax infection detected by PCR (unpublished data). Plasma samples were available for the current study from 41 patients at day 0 (time of enrollment), 7, 14, 28 and 365 (these exact time-points were not always available, exact days post-enrolment are stated in the results and relevant figure legends).…”
Section: Methodsmentioning
confidence: 99%
“…as part of prospective clinical studies in Sabah, Malaysia 20 , 21 . Venous blood was also concurrently collected from healthy asymptomatic adult controls negative for malaria on microscopy and subsequent polymerase chain reaction (PCR) testing 22 . At the time of sampling Sabah had co-endemic transmission of the five aforementioned Plasmodium species.…”
Section: Methodsmentioning
confidence: 99%