2020
DOI: 10.5152/tjar.2019.47936
|View full text |Cite
|
Sign up to set email alerts
|

Comparing I-Gel to Proseal Laryngeal Mask Airways in Infants: A Prospective Randomised Clinical Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0
2

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(11 citation statements)
references
References 15 publications
0
9
0
2
Order By: Relevance
“…A total of 26 trials [ 3 , 9 15 , 17 – 20 , 22 25 , 27 – 28 , 30 – 36 , 40 ] showed that i-gel™ provided a higher rate of first-insertion success [RR = 1.03 (1.0, 1.06), I 2 = 32%, P = 0.03] than LMA ProSeal™ ( Fig 4 ). Exactly 21 trials [ 3 , 9 – 12 , 16 , 17 , 19 , 21 23 , 25 , 28 – 31 , 33 , 34 , 39 41 ] indicated that the insertion ease was substantially higher for i-gel™ than for LMA ProSeal™ [RR = 1.06 (1.01, 1.11), I 2 = 47%, P = 0.01] ( Fig 4 ). In addition, 23 trials [ 3 , 12 – 16 , 19 , 21 25 , 27 – 29 , 31 34 , 36 , 37 , 40 ] showed that SAD intubation time was notably shorter for i-gel™ than for LMA ProSeal™ [MD = -5.61 (-7.71, -3.51), I 2 = 98%, and P<0.00001] ( Fig 5 ).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…A total of 26 trials [ 3 , 9 15 , 17 – 20 , 22 25 , 27 – 28 , 30 – 36 , 40 ] showed that i-gel™ provided a higher rate of first-insertion success [RR = 1.03 (1.0, 1.06), I 2 = 32%, P = 0.03] than LMA ProSeal™ ( Fig 4 ). Exactly 21 trials [ 3 , 9 – 12 , 16 , 17 , 19 , 21 23 , 25 , 28 – 31 , 33 , 34 , 39 41 ] indicated that the insertion ease was substantially higher for i-gel™ than for LMA ProSeal™ [RR = 1.06 (1.01, 1.11), I 2 = 47%, P = 0.01] ( Fig 4 ). In addition, 23 trials [ 3 , 12 – 16 , 19 , 21 25 , 27 – 29 , 31 34 , 36 , 37 , 40 ] showed that SAD intubation time was notably shorter for i-gel™ than for LMA ProSeal™ [MD = -5.61 (-7.71, -3.51), I 2 = 98%, and P<0.00001] ( Fig 5 ).…”
Section: Resultsmentioning
confidence: 99%
“…Exactly 21 trials [ 3 , 9 – 12 , 16 , 17 , 19 , 21 23 , 25 , 28 – 31 , 33 , 34 , 39 41 ] indicated that the insertion ease was substantially higher for i-gel™ than for LMA ProSeal™ [RR = 1.06 (1.01, 1.11), I 2 = 47%, P = 0.01] ( Fig 4 ). In addition, 23 trials [ 3 , 12 – 16 , 19 , 21 25 , 27 – 29 , 31 34 , 36 , 37 , 40 ] showed that SAD intubation time was notably shorter for i-gel™ than for LMA ProSeal™ [MD = -5.61 (-7.71, -3.51), I 2 = 98%, and P<0.00001] ( Fig 5 ). Twelve trials [ 3 , 11 , 14 , 17 , 19 , 21 , 23 , 25 , 27 , 32 , 33 , 40 ] examined the rate of gastric-tube first-insertion success and observed no great difference between the two SADs [RR = 1.04 (0.99, 1.18), I 2 = 66%, and P = 0.11] ( Fig 5 ).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…O I-gel apresentou taxa de sucesso de 100% na primeira tentativa (35) , em consonância com o encontrado na literatura, onde sua inserção é definida como fácil pela maioria dos profissionais que a utilizam (47) . Quando comparado à LMA, o I-gel foi colocado mais rapidamente (35) .…”
Section: Dispositivos De Segunda Geraçãounclassified
“…Quando comparado à LMA, o I-gel foi colocado mais rapidamente (35) . Estudos evidenciaram que a inserção do I-gel foi mais rápida quando comparada com outros tipos de ML (47,48) . O que pode estar relacionado com sua característica de possuir um manguito não inflável (3) .…”
Section: Dispositivos De Segunda Geraçãounclassified