2008
DOI: 10.3928/15428877-20080101-08
|View full text |Cite
|
Sign up to set email alerts
|

Comparing Immersion Ultrasound With Partial Coherence Interferometry for Intraocular Lens Power Calculation

Abstract: When it can be used, interferometry is equivalent to immersion ultrasonography regarding biometric accuracy and precision. However, it cannot replace ultrasonography, especially for eyes with dense media opacity.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
27
1
1

Year Published

2009
2009
2014
2014

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 34 publications
(30 citation statements)
references
References 21 publications
1
27
1
1
Order By: Relevance
“…These data showed the relatively low contribution of error from the axial length source, while the achievement of 0.01 ± 0.20 D error in spectacle plane in 95% of observations has not yet been reached. The reported number of predictions that fall within ±0.5 D, ± 1.0 D, ± 2.0 D of the expected outcome were reached in 55.6-69% [14,20,21]; 87-95.7% [14,20,21,23] and 99.9-100% [20,21] of cases obtained with PCLI biometry. When two methods were compared by Bland-Altman analysis, they demonstrated acceptable agreement for clinical purposes.…”
Section: Discussionmentioning
confidence: 82%
See 2 more Smart Citations
“…These data showed the relatively low contribution of error from the axial length source, while the achievement of 0.01 ± 0.20 D error in spectacle plane in 95% of observations has not yet been reached. The reported number of predictions that fall within ±0.5 D, ± 1.0 D, ± 2.0 D of the expected outcome were reached in 55.6-69% [14,20,21]; 87-95.7% [14,20,21,23] and 99.9-100% [20,21] of cases obtained with PCLI biometry. When two methods were compared by Bland-Altman analysis, they demonstrated acceptable agreement for clinical purposes.…”
Section: Discussionmentioning
confidence: 82%
“…This would be acceptable for clinical purposes, according to the reported number of predictions that fall within ±0.5 D, ± 1.0 D, ± 2.0 D of the expected outcome in 45.5-92% [14,15,20,21]; 77.3-93.5% [14,[20][21][22][23] and 98.4-100% [20][21][22] of cases obtained with ultrasound biometry, respectively.…”
Section: Discussionmentioning
confidence: 96%
See 1 more Smart Citation
“…These data are impressive, because achievement of about 95% of eyes within±0.50 D of the targeted refraction would be an excellent refractive outcome. Reported number of predictions within ±0.5 D, ±1.0 D and ± 2.0 D of the expected outcome was 55.6%-92% [15][16][17][18], 87%-95.7% [15,[17][18][19], and 99.9%-100% [15,18] of cases with PCLI, compared to 45.5%-69.6% [15,17,18], 77.3%-93.5% [15,[17][18][19][20], and 98.4%-100% [15,18,20] of cases with ultrasound respectively.…”
Section: Discussionmentioning
confidence: 99%
“…[1][2][3][4] The new composite IOLMaster version 5 software has demonstrated a failure rate of 7.4%, primarily because of posterior subcapsular cataracts. 5 Few studies of the efficacy of PCI in a teaching hospital setting have been done.…”
Section: Partial Coherence Interferometry In a Teaching Hospitalmentioning
confidence: 99%