Comparison of Abdominal Visceral Adipose Tissue Area Measured by Computed Tomography with That Estimated by Bioelectrical Impedance Analysis Method in Korean Subjects

Abstract: We evaluated the concordance between visceral fat area (VFA) estimated by bioelectrical impedance analysis (BIA) or computed tomography (CT) in Korean subjects with a wide range in age and body mass index (BMI). In 1006 individuals (mean age 55.2 ± 11.8 (19–87) years, mean BMI 26.0 ± 3.5 (17–46) kg/m2, 48.9% men), VFA quantified by CT was compared with VFA using multifrequency BIA machines within 15 days. Concordance rates were compared by age or BMI using correlation analysis, Bland-Altman plots, and intracla… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

5
69
1
2

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 71 publications
(77 citation statements)
references
References 35 publications
5
69
1
2
Order By: Relevance
“…Body weight, BMI, whole fat %, visceral fat level, and whole body subcutaneous fat were measured by Omron Karada Scan HBF-362 Bioelectrical impedance. Th is bioimpedance method of measuring fats has been proven to correlate well with body fat analyzed by Dual-energy X-ray absorptiometry (DEXA) (Fakhrawi et al 2009;Sluyter et al 2010) and even by CT (Lee et al 2015). Each subject was asked to stand barefooted and upright in the middle Brought to you by | MIT Libraries Authenticated Download Date | 5/12/18 1:35 AM of the sensor platform and hold the fat analyzer with his extended arms.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Body weight, BMI, whole fat %, visceral fat level, and whole body subcutaneous fat were measured by Omron Karada Scan HBF-362 Bioelectrical impedance. Th is bioimpedance method of measuring fats has been proven to correlate well with body fat analyzed by Dual-energy X-ray absorptiometry (DEXA) (Fakhrawi et al 2009;Sluyter et al 2010) and even by CT (Lee et al 2015). Each subject was asked to stand barefooted and upright in the middle Brought to you by | MIT Libraries Authenticated Download Date | 5/12/18 1:35 AM of the sensor platform and hold the fat analyzer with his extended arms.…”
Section: Methodsmentioning
confidence: 99%
“…Accurate measurement of the compartmental fat distribution using imaging techniques, as magnetic resonance imaging (MRI) and computed tomography (CT) (Lee et al 2015), are relatively expensive and complex. Th e adiponectin level assay which uses standardized method is also expensive, especially in the clinical risk assessments among large groups of population and large-scale studies.…”
mentioning
confidence: 99%
“…InBody770 (TAKUMI Co., Aichi, Japan) was used to estimate muscle mass, SMI, and body water content. 19,20 InBody770 uses multiple currents at varying frequencies (1 kHz to 1 MHz), which can analyze the intracellular and extracellular water content separately, providing the most precise body water content analysis. Direct segmental measurements can analyze any body type accurately because each segment of the body is assessed separately at multiple frequencies.…”
Section: Methodsmentioning
confidence: 99%
“…Inclusion criteria for white participants were: non-Hispanic white ethnicity; age [25][26][27][28][29][30][31][32][33][34][35] We recruited white participants first, followed by Korean participants to match age and BMI. We screened 56 white people.…”
Section: Participantsmentioning
confidence: 99%
“…Images of amounts of subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) at the umbilical level were taken from MDCT scans as described previously. 27 A cross-sectional abdominal contour was estimated by outlining the skin manually with a graph pen through the muscular structures and lumbar spines. The area between −190 HU and −30 HU pixels was calculated automatically using dedicated software (Rapidia; 3DMED, Seoul, Korea).…”
Section: Abdominal Fat Amount Measurements Using Mdctmentioning