2005
DOI: 10.1016/j.aca.2004.11.065
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of alkaline fusion and acid digestion methods for the determination of rhenium in rock and soil samples by ICP-MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2005
2005
2024
2024

Publication Types

Select...
6
4

Relationship

1
9

Authors

Journals

citations
Cited by 30 publications
(5 citation statements)
references
References 19 publications
0
5
0
Order By: Relevance
“…Many researcher including [7]; and [8]; adopted the digestion test methods to determine the maximum available of metals in soil [8] has used the digestion test method to determine the total phosphors in soil with 5 different reagent included NaCO3 fusion, HClO4 , HCIO4 + HNO3 , HF + HCLO4 or NaOBr oxidation methods., also [9] has used the digestion test to determine trace metals in fly ash by HCl as solution with different concentration and combination of HCl and HNO3. There was no need to use any of methods by other authors because the added lead was not lightly bound and therefore could be released by addition concentrated nitric acid.…”
Section: A Effect Of Leaching Fluidmentioning
confidence: 99%
“…Many researcher including [7]; and [8]; adopted the digestion test methods to determine the maximum available of metals in soil [8] has used the digestion test method to determine the total phosphors in soil with 5 different reagent included NaCO3 fusion, HClO4 , HCIO4 + HNO3 , HF + HCLO4 or NaOBr oxidation methods., also [9] has used the digestion test to determine trace metals in fly ash by HCl as solution with different concentration and combination of HCl and HNO3. There was no need to use any of methods by other authors because the added lead was not lightly bound and therefore could be released by addition concentrated nitric acid.…”
Section: A Effect Of Leaching Fluidmentioning
confidence: 99%
“…For example, 79 Se has stable Se isotopes, however, their concentrations in the environmental samples are quite low; 251 99 Tc has no stable isotope but since the chemical behavior of Re is close to that of Tc, Re can be used as an analogue, but Re concentration data in the environment is also scarce. 251,252 Development of measurement techniques for trace analogous elements has been carried out using ICP-MS; Re in soil, plants and seawater, [253][254][255][256][257] iodine in water, soil, plants, marine biota and marine sediments, [258][259][260][261] Cs and Th in seawater 262,263 are examples. In order to understand 14 C fate in soil-water systems, stable 13 C analysis was also employed.…”
Section: The Fukushima Daiichi Nuclear Power Plant Accident In 2011mentioning
confidence: 99%
“…The procedure for soil and sediment digestion is mainly carried out by alkaline fusion (Uchida et al 2005), acid digestion using mineral acid and heating with a hot plate (Kelepertzis 2014), or applying a microwave-assisted digestion (Marin et al 2008;Roje 2011;Melaku et al 2005). The US Environmental Protection Agency (EPA) has published the methods EPA 3050, 3051, 3051a, and 3052 for acid digestion of soil, sediments, and sludge samples for analysis by AAS, ICP OES, and ICP-MS techniques (Silva et al 2014).…”
Section: Introductionmentioning
confidence: 99%