2011
DOI: 10.1016/j.clinbiochem.2010.10.005
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of blood sirolimus, tacrolimus and everolimus concentrations measured by LC-MS/MS, HPLC-UV and immunoassay methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
38
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 77 publications
(39 citation statements)
references
References 31 publications
1
38
0
Order By: Relevance
“…Several studies have already reported similar results without any additional explanation [18,19]. Since we compared the results obtained from simultaneous UV and MS analysis here, samples or standard preparations could not be implicated in these variations.…”
Section: Comparison Of the Uhplc-uv And Uhplc-ms/ms Methodssupporting
confidence: 62%
See 1 more Smart Citation
“…Several studies have already reported similar results without any additional explanation [18,19]. Since we compared the results obtained from simultaneous UV and MS analysis here, samples or standard preparations could not be implicated in these variations.…”
Section: Comparison Of the Uhplc-uv And Uhplc-ms/ms Methodssupporting
confidence: 62%
“…This time analysis is longer than that reported by Ceyman et al [17]. We chose to increase analysis time to separate all major phenolic compounds present in apple juice, especially to avoid, as much as possible, co-elutions that may affect UV and mass quantifications due to possible matrix effects already reported by other authors [18,19]. The chromatogram obtained under these conditions is available to quantify 25 additional compounds identified primarily as polymeric flavanols, subject to the availability of standards.…”
Section: Uhplc-uv and Uhplc-ms/ms Conditionsmentioning
confidence: 99%
“…[10][11][12][13] The benefits of sensitivity, specificity, and multiple reaction monitoring make liquid chromatography tandem mass spectrometry (LC-MS/MS) a useful alternative. 7,14,15 Several LC-MS/MS methods are available for the measurement of sirolimus and/or everolimus.…”
Section: Introductionmentioning
confidence: 99%
“…A number of works establish suitable liquid chromatography-mass spectrometry detection (LC-MS) methods, which grant accurate RAD001 dosage in clinical samples on a high throughput regime also with online purification steps [4][5][6][7][8][9][10][11]. However, biological matrix effects represent a serious pitfall in drug quantitation due to potential interferences [12].…”