“…For the second line of bolts, only this method gives similar results to the FE analysis. Very similar experimental and finite element results were also gained by other researchers dealing with the pretensioned bolted endplate connections [9], [13], [16] to [21] Based on the results it can be concluded that the analytical method presented in this paper is the most accurate. Nevertheless these results do deviate slightly from the FE analysis but these deviations are acceptable.…”
Section: Comparison Of Resultssupporting
confidence: 72%
“…For the second line of bolts, only this method gives similar results to the FE analysis. Very similar experimental and finite element results were also gained by other researchers dealing with the pretensioned bolted endplate connections [9], [13], [16] to [21] Based on the results it can be concluded that the analytical method presented in this paper is the most accurate. Nevertheless these results do deviate slightly from the FE analysis but these deviations are acceptable.…”
Section: Comparison Of Resultssupporting
confidence: 72%
“…They reported that the rotation capacities of the test specimens satisfied the ductility design requirements of earthquake‐resistance for most seismic regions. Saberi et al () investigated the behavior of bolted connections as a function of the thicknesses of the end plate and T‐stub flange using a numerical method. In their results, they pointed out that the performance of bolted T‐stub connections is more sensitive to component thickness than end plate connections Muresan and Balc () demonstrated experimental results where increased displacement occurred around the tension flange of the connection.…”
Section: Introductionmentioning
confidence: 99%
“…Yapılan çalışma sonucunda, T kesit levhalı birleşimlerin levha kalınlığı değişimine daha hassas oldukları görülmüştür. Her iki birleşim türünde de levha kalınlığının azalmasıyla, maksimum momente daha yüksek dönme değerlerinde ulaşıldığı görülmüştür [14]. Shaker ve Abd Elrahman alın levhalı birleşimlerde alın levhası kalınlığı, bulon çapı, kolonda süreklilik levhası olup olmaması değişimlerini incelemek için [1]'de verilen modellemelerden faydalanmışlardır [15].…”
Section: şEkilunclassified