2015
DOI: 10.18857/jkpt.2015.27.1.50
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Cervical Flexor Muscles Thickness During Cranial-Cervical Flexor Exercise According to Pressure Levels and Eye Directions in Healthy Subjects

Abstract: Purpose:The purpose of this study is to investigate differences of cervical flexor muscle thickness (i.e., sternocleidomastoid muscle and deep cervical flexor muscles) depending on levels of pressure bio-feedback unit and eye directions during cranial-cervical flexor exercise in healthy subjects. Methods: A total of 30 subjects (12 males and 18 females) who had no medical history related to musculoskeletal and neurological disorders were enrolled in this study. They were instructed to perform cranial-cervical … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 15 publications
0
6
0
Order By: Relevance
“…The CCFT is generally performed while looking slightly downward [ 19 ]. For individuals without CNP, DNF and SCM activation has been shown to change according to gaze direction in the CCFT [ 30 ]. In this study, changes in LC and SCM muscle thickness were measured using ultrasound images.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…The CCFT is generally performed while looking slightly downward [ 19 ]. For individuals without CNP, DNF and SCM activation has been shown to change according to gaze direction in the CCFT [ 30 ]. In this study, changes in LC and SCM muscle thickness were measured using ultrasound images.…”
Section: Discussionmentioning
confidence: 99%
“…The DNF contracted ratio maintained a similar value as the degree of gaze direction increased, but, in contrast, the SCM contracted ratio increased as the degree of gaze direction increased. In a study that applied the CCFT to individuals without CNP, the SCM contracted ratio increased as the degree of gaze direction gradually increased to below 20° and below 40° [ 30 ]. In previous studies, SCM activation showed a specific pattern of increase with increasing gaze direction and direction of rotation angle (0°, 15°, 30°, and 45°) [ 31 ].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The pressure biofeedback device consists of a meter and a flat pocket pneumatic pump, where the force generated by the contraction of the deep muscles is transferred to the pressure biofeedback device to measure the pressure. The unit is mmHg [16] (Figure 2).…”
Section: Measurement Toolsmentioning
confidence: 99%