2018
DOI: 10.1016/j.jpowsour.2018.06.087
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of chronoamperometric response and rate-performance of porous insertion electrodes: Towards an accelerated rate capability test

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
36
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 25 publications
(37 citation statements)
references
References 22 publications
1
36
0
Order By: Relevance
“…Wong et al[30] used equation 5 to fit a large number of Q/M v CR data sets from the literature. They found correlations between  and various electrode parameters such as particle size and the activation energy associated with solid state diffusion (with the latter relationship implying an inverse scaling between  and solid-state diffusion coefficient, consistent with equation 3 and equation 12 below).Equations 6 and 7 were both derived[31] using methods[35] designed to convert chronoamperometry data to capacity-rate data. These equations have the advantage that they have some physical basis, are expressed in a simple form and fit experimental data well.…”
mentioning
confidence: 71%
“…Wong et al[30] used equation 5 to fit a large number of Q/M v CR data sets from the literature. They found correlations between  and various electrode parameters such as particle size and the activation energy associated with solid state diffusion (with the latter relationship implying an inverse scaling between  and solid-state diffusion coefficient, consistent with equation 3 and equation 12 below).Equations 6 and 7 were both derived[31] using methods[35] designed to convert chronoamperometry data to capacity-rate data. These equations have the advantage that they have some physical basis, are expressed in a simple form and fit experimental data well.…”
mentioning
confidence: 71%
“…To understand individual contributions of Si and Gr to the rate capability of Si/Gr blended electrodes, rate performance tests based on chronoamperometry [74,75] were carried out using Si/Gr MLBE. Figure 4a shows the deconvoluted capacity as a function of the C‐rate obtained from a Si/Gr MLBE ( m Si : m Gr 1 : 19) for the case of lithiation.…”
Section: Resultsmentioning
confidence: 99%
“…8 The cells were first tested via GCD measurements (BioLogic VMP-3. Three cycles were performed between Current transients from CA were converted to specific capacity (Q/M) vs. rate (R) curves using the following equations: 8,22 ( )…”
Section: Electrochemical Measurementsmentioning
confidence: 99%