2013
DOI: 10.1016/j.acra.2013.06.002
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Fenestra LC, ExiTron nano 6000, and ExiTron nano 12000 for Micro-CT Imaging of Liver and Spleen in Mice

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
63
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 44 publications
(64 citation statements)
references
References 21 publications
1
63
0
Order By: Relevance
“…Contrast was diluted 1:1 in sterile saline (50 μL contrast per animal, equivalent to ~640 mg iodine/kg body weight). Because this agent is taken up by cells of the reticuloendothelial system, it provides excellent contrast in liver and spleen lasting several weeks after injection (Supplemental Fig 1), and it has demonstrated low toxicity in small animal imaging (Boll et al, 2013; Boll et al, 2011). CT scans were performed at three different time points: pre-contrast, 2 h after contrast injection, and 2 weeks after capture.…”
Section: ) Materials and Methodsmentioning
confidence: 99%
“…Contrast was diluted 1:1 in sterile saline (50 μL contrast per animal, equivalent to ~640 mg iodine/kg body weight). Because this agent is taken up by cells of the reticuloendothelial system, it provides excellent contrast in liver and spleen lasting several weeks after injection (Supplemental Fig 1), and it has demonstrated low toxicity in small animal imaging (Boll et al, 2013; Boll et al, 2011). CT scans were performed at three different time points: pre-contrast, 2 h after contrast injection, and 2 weeks after capture.…”
Section: ) Materials and Methodsmentioning
confidence: 99%
“…To reduce skin doses, a 0.5 mm aluminium filter was used [29, 30]. Raw-data were reconstructed using a filtered back projection algorithm with a matrix of 512 x 512 x 512 (Reconstruction Studio, Tera Recon) [17, 18, 31, 32] and a smooth band-pass filter method, which we evaluated to provide the best soft tissue contrast. In-plane resolution was 40x40 μm.…”
Section: Methodsmentioning
confidence: 99%
“…Most currently commercially available MicroCT contrasts can be generally subdivided into particulate non-metabolizable macrophage specific and polydisperse metabolizable iodine-based contrasts 23,[33][34][35][36] . Although particulate agents offer greater X-ray opacification due to their higher atomic number (barium, Z=56; and gold, Z=79), they cannot be used for metabolic assessment.…”
Section: Discussionmentioning
confidence: 99%