2012
DOI: 10.1016/j.sab.2012.05.013
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of inductively coupled plasma mass spectrometry and colorimetric determination of total and extractable phosphorus in soils

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 32 publications
(21 citation statements)
references
References 15 publications
0
21
0
Order By: Relevance
“…Chemical element analysis using ICP-MS has many advantages, especially allowing the simultaneous determination of broad range of element identification in geoarchaeological studies (Entwistle and Abrahams, 1997;Ivanov et al, 2012). The drawback of spectrometry techniques is that they first require the solid sample to be transformed into solution (Sastre et al, 2002).…”
Section: Discussionmentioning
confidence: 99%
“…Chemical element analysis using ICP-MS has many advantages, especially allowing the simultaneous determination of broad range of element identification in geoarchaeological studies (Entwistle and Abrahams, 1997;Ivanov et al, 2012). The drawback of spectrometry techniques is that they first require the solid sample to be transformed into solution (Sastre et al, 2002).…”
Section: Discussionmentioning
confidence: 99%
“…The soil pH was determined by potentiometry in 1 mol·dm -3 KCl suspension, whereas available sulfur was extracted with 0.03 mol·dm -3 acetic acid (10:1 (v:m), 30 min, 40 RPM) (Ostrowska et al, 1991). Available phosphorus was determined by Egner-Riehm method (Ivanov et al, 2012), after extraction with calcium lactate at pH 3.55 (5:1 (v:m), 90 min, 40 RPM). The sulfur and phosphorus content in the solutions was determined using inductively coupled plasma optical emission spectrometry (ICP-OES), using a Perkin Elmer Optima 7300 DV spectrometer.…”
Section: Methodsmentioning
confidence: 99%
“…These parameters estimate the labile C and P fraction of the soil. To measure the total P content of the soil, the method of Ivanov et al (2012) for a microwave digestion method was used as follows: 0.5000 g of oven-dry soil (70 C, <250 mm) was destructed for 30 min at 200 C in 12 ml aqua regia in a microwave oven. After filtration on a Whatman 640 d filter, the P concentration of the filtrate was measured with ICP-OES.…”
Section: Soil Analysismentioning
confidence: 99%