2009
DOI: 10.1007/s10064-009-0191-4
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of liquid limit values determined using the hard and soft base Casagrande apparatus and the cone penetrometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
14
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 39 publications
(18 citation statements)
references
References 15 publications
4
14
0
Order By: Relevance
“…Of 19 re la tion ships pub lished in the lit er a ture (Ta ble 1), 12 tend to be sim i lar to the cor re la tion de rived in the cur rent ar ti cle (Ta ble 2), and the re main ing seven dif fer no tice ably. Seven of the au thors sug gested that the liq uid limit value de ter mined in the cone pen etrom eter is al ways greater than that de ter mined in the Casagrande ap pa ra tus (Sampson and Netterberg, 1985;Wasti and Bezirci, 1986;Queiroz de Carvalho, 1986;Orhan et al, 2006;Dragoni et al, 2008;Fojtová et al, 2009;Di Matteo, 2012), and 12 of them claim that, in the higher range of the w L value (above the point of equiv a lent re sults), the Casagrande ap pa ra tus gives higher w L val ues than the cone pen etrom eter (Wires, 1984;Belviso et al, 1985;Budhu, 1985;Leroueil and Le Bihan, 1996;Sridharan et al, 1999;Özer, 2009;GrÝnbech et al, 2011;Spagnoli, 2012).…”
Section: The Point Of Equivalent Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Of 19 re la tion ships pub lished in the lit er a ture (Ta ble 1), 12 tend to be sim i lar to the cor re la tion de rived in the cur rent ar ti cle (Ta ble 2), and the re main ing seven dif fer no tice ably. Seven of the au thors sug gested that the liq uid limit value de ter mined in the cone pen etrom eter is al ways greater than that de ter mined in the Casagrande ap pa ra tus (Sampson and Netterberg, 1985;Wasti and Bezirci, 1986;Queiroz de Carvalho, 1986;Orhan et al, 2006;Dragoni et al, 2008;Fojtová et al, 2009;Di Matteo, 2012), and 12 of them claim that, in the higher range of the w L value (above the point of equiv a lent re sults), the Casagrande ap pa ra tus gives higher w L val ues than the cone pen etrom eter (Wires, 1984;Belviso et al, 1985;Budhu, 1985;Leroueil and Le Bihan, 1996;Sridharan et al, 1999;Özer, 2009;GrÝnbech et al, 2011;Spagnoli, 2012).…”
Section: The Point Of Equivalent Resultsmentioning
confidence: 99%
“…Lab o ra tory test ing car ried out in the cur rent study in cluded mac ro scopic anal y sis of soil sam ples, de ter mi na tion of nat u ral mois ture con tent, grain-size anal y sis us ing both hy drom e ter and sieve meth ods, and de ter mi na tion of the plas tic limit and liq uid limit in the cone pen etrom eter with a 30°/80 g cone and in the Casagrande ap pa ra tus with the so-called hard base (PN-88/B-04481, 1988;PKN-CEN ISO/TS 17892-1, 4, 12, 2009). It needs to be pointed out that the hard ness of the rubber from which the Casagrande ap pa ra tus base is made signif i cantly in flu ences the liq uid limit value (Nor man, 1958;Özer, 2009). The softer the ma te rial from which the base is made, the higher the w L value.…”
Section: Tested Soils and Testing Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The reference for each equation is presented along with the range of LL values for each case. (Wasti, 1987;Prakash and Sridharan, 2006;Özer, 2009). In general, good agreement is observed for soils within an approximate range of 0%<LL<70%.…”
Section: Correlation Of Llcup and Llconementioning
confidence: 89%
“…In the professional literature worldwide, there are many publications that attempt to correlate the results obtained with the Casagrande apparatus and the cone penetrometer (Wires, 1984;Budhu, 1985;Wasti, 1987;Christaras, 1991;Leroueil & Le Bihan, 1996;Suchnicka, 1999;Ozer & Isik, 2006;Prosperini & Vinti, 2008;Franeková, & Kovàr, 2009;Özer, 2009;Dragoni, Fojtová, Marschalko, Grønbech, Nielsen & Ibsen, 2011;Di Matteo, 2012;Orhan, Spagnoli, 2012;Jaśkiewicz & Wszędyrówny-Nast, 2013;Hrubesova, Lunackova & Brodzki, 2016). They focus mainly on comparing only the w L value.…”
Section: The Value Of Plasticity Index (I P ) and Liquidity Index (I mentioning
confidence: 99%