Comparison of NEMA NU 4-2008 vs NEMA NU 2-2001 for the performance evaluation of the microPET R4 system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
8
0

Year Published

2010
2010
2018
2018

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 2 publications
2
8
0
Order By: Relevance
“…Despite the fact that the performance assessment of many small animal PET scanners developed in academic and corporate settings based on the NEMA NU 4-2008 standards is documented in the recent literature (Popota et al 2009, Bao et al 2009, Lage et al 2009, Kis et al 2009, Bahri et al 2009, Kemp et al 2009, Disselhorst et al 2010, Prasad et al 2010, to the best of our knowledge, there is a lack of the published scientific literature reporting on the performance characterization of the LabPET-8 TM system using these standards. The FBP reconstructed spatial resolution shows that the tangential spatial resolution does not vary significantly throughout the transverse FOV.…”
Section: Discussionmentioning
confidence: 99%
“…Despite the fact that the performance assessment of many small animal PET scanners developed in academic and corporate settings based on the NEMA NU 4-2008 standards is documented in the recent literature (Popota et al 2009, Bao et al 2009, Lage et al 2009, Kis et al 2009, Bahri et al 2009, Kemp et al 2009, Disselhorst et al 2010, Prasad et al 2010, to the best of our knowledge, there is a lack of the published scientific literature reporting on the performance characterization of the LabPET-8 TM system using these standards. The FBP reconstructed spatial resolution shows that the tangential spatial resolution does not vary significantly throughout the transverse FOV.…”
Section: Discussionmentioning
confidence: 99%
“…To the best of our knowledge, there is a lack of published reports on performance evaluation of the FLEX Triumph X-PET system based on NEMA NU 4-2008 standards. However, a few articles documented the performance assessment of other preclinical PET scanners using these standards (16)(17)(18)(19)(20).…”
Section: Discussionmentioning
confidence: 99%
“…They also document operational PET scanner performance as part of the quality-assurance program. However, until now few papers reported on the performance characterization of dedicated preclinical PET scanners using the NU 4-2008 standards (16)(17)(18)(19)(20). This work evaluates the overall performance characteristics of the X-PET subsystem of the FLEX Triumph preclinical PET/CT platform using the NEMA NU 4-2008 standards, including spatial resolution, scatter fraction, count losses and random coincidence measurements, sensitivity, and image-quality characteristics.…”
mentioning
confidence: 99%
“…During the evaluation of the scatter fraction and count rate performance according to the NEMA NU 2-2001 [21], bigger phantoms were used as well as different energy windows [32]. For example, according to Knoess et al.…”
Section: Discussionmentioning
confidence: 99%