1995
DOI: 10.1016/0360-3016(95)00275-8
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of static conformal field with multiple noncoplanar arc techniques for stereotactic radiosurgery or stereotactic radiotherapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
23
0

Year Published

1998
1998
2015
2015

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 65 publications
(23 citation statements)
references
References 13 publications
0
23
0
Order By: Relevance
“…The mean dose to the total brain increased which can be explained by the increase in dose heterogeneity and the larger volume receiving lower doses which is characteristic of conformal treatment methods. 35 The results of this study represent a small but significant step in the treatment of MB and provide a basis for further dose reductions in these patients. Our current trial includes further reductions in dose and volume: patients with average risk MB now receive 23.4 Gy CSI followed by treatment of the primary site using a 1 cm clinical target volume margin and the same chemotherapy.…”
Section: Discussionmentioning
confidence: 84%
“…The mean dose to the total brain increased which can be explained by the increase in dose heterogeneity and the larger volume receiving lower doses which is characteristic of conformal treatment methods. 35 The results of this study represent a small but significant step in the treatment of MB and provide a basis for further dose reductions in these patients. Our current trial includes further reductions in dose and volume: patients with average risk MB now receive 23.4 Gy CSI followed by treatment of the primary site using a 1 cm clinical target volume margin and the same chemotherapy.…”
Section: Discussionmentioning
confidence: 84%
“…This is realized by using dedicated MLC system with smaller leaves. Studies have shown that, with smaller MLC leaves, linear accelerator‐based SRS with multiple static beams allows better normal tissue sparing for irregular shaped targets than the multiple arching beams using the circular collimators 18 , 19 . One of the important studies to assess the impact of MLC on dose distribution was performed by Bortfeld et al (4) They showed that theoretically calculated optimum leaf width for 6 MV photon beam was in the range of 1.52.0 mm.…”
Section: Discussionmentioning
confidence: 99%
“…For Iinac-based SRS with circular collimators, the planner strives to minimize the number of isocenters in a plan due to the inefficient beam delivery (28)(29)(30). For linac-based SRS with mMLCs, only one isocenter is used (4,(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18). The planning methods are similar to the planning for external beam radiation therapy.…”
Section: Yu and Shepardmentioning
confidence: 99%
“…These include the use of multiple fixed fields (4,(7)(8)(9)(10)(11)(12)(13)(14)(15), dynamic conformal arcs (17,18), multiple fixed intensity-modulated fields with inverse planning (9,16). In some planning systems, the weights of the beams and/or arcs can be optimized (16).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation