2019
DOI: 10.1016/j.brachy.2018.08.007
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of two iodine-125 brachytherapy implant techniques for the treatment of lung tumor: Preplanning and intraoperative planning

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 26 publications
0
6
0
Order By: Relevance
“…Then, clinical target volume (CTV) was generated by adding a margin of 5-mm to gross tumor volume (GTV) in all directions. The CTV was equal to the target volume [12,13,14]. We outlined a 2-mm thick contour below the skin surface standing for skin [15].…”
Section: Methodsmentioning
confidence: 99%
“…Then, clinical target volume (CTV) was generated by adding a margin of 5-mm to gross tumor volume (GTV) in all directions. The CTV was equal to the target volume [12,13,14]. We outlined a 2-mm thick contour below the skin surface standing for skin [15].…”
Section: Methodsmentioning
confidence: 99%
“…They suggested that V100, V150, and V200 for the intraoperative planning technique were significantly higher than that for the preplanning technique (95.65% vs. 88.86%, 76.47% vs. 69.23%, and 59.80% vs. 28.30%, respectively, p < 0.01). In addition, intraoperative planning had a significantly higher coverage index, conformity index plan, and quality index (p < 0.05) and a lower dose homogeneity index compared with the preplanning technique ( 49 ). When it comes to the improved accuracy brought by 3D-PT, Liu et al.…”
Section: Physical Aspectsmentioning
confidence: 99%
“…For instance, Li et al. ( 49 ) reported that intraoperative planning was superior to the preplanning technique, via comparing the difference of dosimetry parameter between preplanning and intraoperative planning in I-125 BT for lung cancer. They suggested that V100, V150, and V200 for the intraoperative planning technique were significantly higher than that for the preplanning technique (95.65% vs. 88.86%, 76.47% vs. 69.23%, and 59.80% vs. 28.30%, respectively, p < 0.01).…”
Section: Physical Aspectsmentioning
confidence: 99%
“… 24 Additionally, intraoperative planning methods were more effective than pre-planning methods for treating lung tumors, as demonstrated by comparing V 100 , V 150 , V 200 , CI, COIN, plan quality index, and HI. 25 However, comparing 125 I seed implantation therapy and external radiotherapy is challenging because it is difficult to accurately convert the absorbed dose of brachytherapy into that of external radiotherapy.…”
Section: Basics and Principles Of 125 I Seed Impla...mentioning
confidence: 99%