2002
DOI: 10.1002/jbm.10310
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of two methods to measure permeability of dentin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0
1

Year Published

2007
2007
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 20 publications
0
5
0
1
Order By: Relevance
“…The stepwise shape, containing several parts with no recorded additional movement during several seconds (Fig. 8 ) also indicates that “very short” measurement periods or even discontinuous measurements may lead to incorrect results 50 . We decided not to include longer measurement periods which are sometimes reported, e.g.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The stepwise shape, containing several parts with no recorded additional movement during several seconds (Fig. 8 ) also indicates that “very short” measurement periods or even discontinuous measurements may lead to incorrect results 50 . We decided not to include longer measurement periods which are sometimes reported, e.g.…”
Section: Discussionmentioning
confidence: 99%
“…To address this, we standardized the duration of the measurements to 2 min and discarded 15 s each from the beginning and the end to avoid any handling influences. The Flodec system, used frequently in the literature 49 , 50 , continuously recorded a fluid flow through the dentin slices by measuring the movement of a water-to-air interface within an internal circular glass capillary of constant diameter (according to manufacturers’ information). The pressure applied (1.4 m H 2 O = 13.8 kPa) was within the range (1.38–34.47 kPa) reported in the literature 40 , 49 .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…4,5,22 One limitation of the method is that the etched dentin disks, when kept in deionized water for more than 1 week, partially lose their maximum permeability. Because of this, a large number of teeth must be collected (in our case, 220 teeth) to achieve the expected number of samples for a limited time of storage (n=8 per group; 56 disks).…”
Section: Discussionmentioning
confidence: 99%
“…와동형성이나 충전과 같은 수복행위나 상아질과민증과 관 련하여 상아세관액의 미세이동을 정량적으로 측정하려는 노 력으로는, Brännstorm 등 4,6,7,9) 이 치근에 모세관을 연결하 여 상아질의 수분투과도를 측정하였고, 최근에는 발전된 전 자-기계공학 서보기술을 이용하여 거의 실시간으로 상아질 을 통한 수분이동을 측정할 수 있게 되었다. 이중 대표적인 장치는 Flodec (De Marco Engineering, Geneva, Switzerland)이란 측정장치로서 많은 연구자들이 이를 이 용하여 상아질의 수분투과도 10,11) , 치아과민증 치료제나 상 아질접착제의 상아세관 밀폐효과 [12][13][14][15] , 복합레진 수복과정이 상아세관액의 이동에 미치는 영향 [16][17][18] , 근관충전재의 밀폐 효과 19 . 둘 째, 치수의 정수압은 30 mmHg 정도가 되는 것으로 알려 져 있다 3,5,7,16) .…”
Section: ⅰ 서 론unclassified