2001
DOI: 10.1002/ffj.1034
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of volatile compounds released during the consumption of Cheddar cheese with compounds extracted by vacuum distillation using gas chromatography–olfactometry

Abstract: Buccal headspace analysis is an in vivo extraction technique capable of extracting volatile compounds released during consumption in concentration ratios that stimulate the olfactory receptors. Vacuum distillation is designed to measure the total volatile profile of a food and as a result pays little attention to conditions in the mouth that determine volatile release and aroma stimulation. Volatile extracts of mature Cheddar cheese were obtained using buccal headspace analysis and vacuum distillation. Cheddar… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
0

Year Published

2002
2002
2012
2012

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 27 publications
(19 citation statements)
references
References 13 publications
(26 reference statements)
0
19
0
Order By: Relevance
“…Direct-intensity data have been recorded using a variable resistor [7,28], a variable rheostat activated by finger span [8,31,32] or an on-screen scale using a mouse [8]. Use of a pressure-resistant device or button has also been used [50]. Pollien et al [3] believed that it would be difficult for assessors to concentrate on detecting odours, continuously evaluating intensity and assigning descriptions at the same time.…”
Section: Methods Of Recording Datamentioning
confidence: 99%
See 4 more Smart Citations
“…Direct-intensity data have been recorded using a variable resistor [7,28], a variable rheostat activated by finger span [8,31,32] or an on-screen scale using a mouse [8]. Use of a pressure-resistant device or button has also been used [50]. Pollien et al [3] believed that it would be difficult for assessors to concentrate on detecting odours, continuously evaluating intensity and assigning descriptions at the same time.…”
Section: Methods Of Recording Datamentioning
confidence: 99%
“…Delahunty et al [9] used an unstructured sliding scale to record both odour intensity and odour duration dynamically (1 datapoint per second during the GC run). In addition, a spring-loaded button (i. e. incorporating a renewable resistance to pressure) has been used [50]. This device allowed each assessor to relate perceived odour intensity to the physical stimulus of hand pressure, thereby improving the reliability of recorded odour intensity data.…”
Section: Methods Of Recording Datamentioning
confidence: 99%
See 3 more Smart Citations