1989
DOI: 10.1021/es00065a015
|View full text |Cite
|
Sign up to set email alerts
|

Complete characterization of polychlorinated biphenyl congeners in commercial Aroclor and Clophen mixtures by multidimensional gas chromatography-electron capture detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

10
285
2
7

Year Published

1994
1994
2005
2005

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 633 publications
(304 citation statements)
references
References 15 publications
10
285
2
7
Order By: Relevance
“…Individual PCB congeners, 2,2′, 4,4′-tetrachlorobiphenyl (CB47), 2,2′,5,5′-tetrachlorobiphenyl (CB52), 2,3′,4,4′,5-pentachlorobiphenyl (CB118), 2,2′,4,4′,5,5′-hexachlorobiphenyl (CB153), were synthesized as previously described [50,51]. The PCB mixtures, Clophen A30, Clophen A40, Clophen A50 and Clophen A60 are former commercially available PCB products (Bayer AG, Germany) [52].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Individual PCB congeners, 2,2′, 4,4′-tetrachlorobiphenyl (CB47), 2,2′,5,5′-tetrachlorobiphenyl (CB52), 2,3′,4,4′,5-pentachlorobiphenyl (CB118), 2,2′,4,4′,5,5′-hexachlorobiphenyl (CB153), were synthesized as previously described [50,51]. The PCB mixtures, Clophen A30, Clophen A40, Clophen A50 and Clophen A60 are former commercially available PCB products (Bayer AG, Germany) [52].…”
Section: Methodsmentioning
confidence: 99%
“…The major constituent in the PCB products A30, A40, A50, and A60 are tri-chlorinated biphenyls (48%), tetra-chlorinated biphenyls (52%), penta-chlorinated biphenyls (55%) and hexa-chlorinated biphenyls (54%), respectively [52]. Further, the percentage of low-chlorinated biphenyls (tetra-chlorinated or lower) in the four PCB products A30, A40, A50, and A60, are 93%, 70%, 19%, and 1%, respectively.…”
Section: Effects Of Pcbs On the Biosynthesis Of 12-hete And 12-hht Inmentioning
confidence: 99%
“…CB-138 co-elutes with CB-158, but since they have identical TEFs (0.00002) the concentration measured as CB-138 equivalents is applied for the calculation of TEQs. CB-170 co-elutes with CB-190 (Schulz et al, 1989). The same reasoning as for CB-156/-171 is valid for these two pairs of congeners.…”
Section: Pcb Analyses In Adipose Tissuementioning
confidence: 57%
“…None of the non-ortho-substituted PCBs (CBs -77, -126 and -169) can be determined. Of these congeners, only CB-126 is measurably present in CloA50 (Schulz et al, 1989). Of the mono-ortho-substituted PCBs present in CloA50, CB-105 and CB-118 can be determined unequivocally.…”
Section: Pcb Analyses In Adipose Tissuementioning
confidence: 92%
See 1 more Smart Citation