2005
DOI: 10.1186/1468-6708-6-17
|View full text |Cite
|
Sign up to set email alerts
|

Compliance of a cobalt chromium coronary stent alloy – the COVIS trial

Abstract: Background: Cobalt chromium coronary stents are increasingly being used in percutaneous coronary interventions. There are, however, no reliable data about the characteristics of unfolding and visibility of this stent alloy in vivo. The aim of this study is to compare cobalt chromium coronary stents with conventional stainless steel stents using intracoronary ultrasound.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0
2

Year Published

2007
2007
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 19 publications
(10 citation statements)
references
References 6 publications
0
8
0
2
Order By: Relevance
“…Como outros atrativos, esse stent possui moderna plataforma de cobalto-cromo, de hastes muito finas, mas com boa radiopacidade, tendo demonstrado excelente navegabilidade em estudos pré-clínicos 13 .…”
Section: Discussionunclassified
“…Como outros atrativos, esse stent possui moderna plataforma de cobalto-cromo, de hastes muito finas, mas com boa radiopacidade, tendo demonstrado excelente navegabilidade em estudos pré-clínicos 13 .…”
Section: Discussionunclassified
“…The platform of the Xience V stent is a L-605 cobalt chromium (CoCr) balloon expandable stent remarkably similar to its successful BMS equivalent, the Multi-Link Vision ® (Abbott Laboratories), whose main characteristics are low strut thickness, high flexibility and deliverability, acceptable compliance, recoil and risk of plaque prolapse, and overall good radiopacity (Hagemeister et al 2005; Tanimoto et al 2007). The performance of the Multi-Link Vision has already been proved in clinical practice, and this stent is among the most commonly used worldwide (Kaiser et al 2005; Ortolani et al 2007; Xu et al 2007).…”
Section: Design and Pharmacology Of The Xience V Stent And Preclinicamentioning
confidence: 99%
“…The platform of the Xience V stent is a L-605 cobalt chromium (CoCr) balloon expandable stent remarkably similar to its successful BMS equivalent, the Multi-Link Vision ® Xience V everolimus-eluting stent (Abbott Laboratories), whose main characteristics are low strut thickness, high fl exibility and deliverability, acceptable compliance, recoil and risk of plaque prolapse, and overall good radiopacity (Hagemeister et al 2005;Tanimoto et al 2007). The performance of the Multi-Link Vision has already been proved in clinical practice, and this stent is among the most commonly used worldwide (Kaiser et al 2005;Ortolani et al 2007;Xu et al 2007).…”
Section: Design and Pharmacology Of The Xience V Stent And Preclinicamentioning
confidence: 99%