BACKGROUND: Patients at high risk for bleeding who undergo percutaneous coronary intervention (PCI) often receive bare-metal stents followed by 1 month of dual antiplatelet therapy. We studied a polymer-free and carrier-free drug-coated stent that transfers umirolimus (also known as biolimus A9), a highly lipophilic sirolimus analogue, into the vessel wall over a period of 1 month. METHODS: In a randomized, double-blind trial, we compared the drug-coated stent with a very similar bare-metal stent in patients with a high risk of bleeding who underwent PCI. All patients received 1 month of dual antiplatelet therapy. The primary safety end point, tested for both noninferiority and superiority, was a composite of cardiac death, myocardial infarction, or stent thrombosis. The primary efficacy end point was clinically driven target-lesion revascularization. RESULTS: We enrolled 2466 patients. At 390 days, the primary safety end point had occurred in 112 patients (9.4%) in the drug-coated-stent group and in 154 patients (12.9%) in the bare-metal-stent group (risk difference, -3.6 percentage points; 95% confidence interval [CI], -6.1 to -1.0; hazard ratio, 0.71; 95% CI, 0.56 to 0.91; P<0.001 for noninferiority and P=0.005 for superiority). During the same time period, clinically driven target-lesion revascularization was needed in 59 patients (5.1%) in the drug-coated-stent group and in 113 patients (9.8%) in the baremetal-stent group (risk difference, -4.8 percentage points; 95% CI, -6.9 to -2.6; hazard ratio, 0.50; 95% CI, 0.37 to 0.69; P<0.001). CONCLUSIONS: Among patients at high risk for bleeding who underwent PCI, a polymer-free umirolimus-coated stent was superior to a bare-metal stent with respect to the primary safety and efficacy end points when used with a 1-month course of dual antiplatelet therapy. (Funded by Biosensors Europe; LEADERS FREE ClinicalTrials.gov number, NCT01623180.).
Alongside other established clinical risk factors, procedural complexity is an important parameter to take into account in tailoring upfront duration of DAPT.
Bioprostheses are prone to structural valve degeneration, resulting in limited long-term durability. A significant challenge when comparing the durability of different types of bioprostheses is the lack of a standardized terminology for the definition of a degenerated valve. This issue becomes especially important when we try to compare the degeneration rate of surgically inserted and transcatheter bioprosthetic valves. This document, by the VIVID (Valve-in-Valve International Data), proposes practical and standardized definitions of valve degeneration and provides recommendations for the timing of clinical and imaging follow-up assessments accordingly. Its goal is to improve the quality of research and clinical care for patients with deteriorated bioprostheses by providing objective and strict criteria that can be utilized in future clinical trials. We hope that the adoption of these criteria by both the cardiological and surgical communities will lead to improved comparability and interpretation of durability analyses.
We studied 954 consecutive patients with native coronary artery lesions treated with elective Palmaz-Schatz stents implantation using conventional coronary angiographic and intravascular ultrasound methodology. Procedural success, major in-hospital complications, and 1-year clinical outcome were compared according to the diabetic status. RESULTS. In-hospital mortality was 2% in IDDM, significantly higher (p <0.02) compared with non-IDDM (0%) and nondiabetics (0.3%). Stent thrombosis did not differ among groups (0.9% in IDDM vs. 0% in non-IDDM and 0% in nondiabetics, p >0.1). During follow-up, target lesion revascularization (TLR) was 28% in IDDM, significantly higher (p <0.05) compared with non-IDDM (17.6%) and nondiabetics (16.3%). Late cardiac event-free survival (including death, myocardial infarction [MI], and any coronary revascularization procedure) was significantly lower (p=0.0004) in IDDM (60%) compared with non-IDDM (70%) and nondiabetic patients (76%). By multivariate analysis, IDDM was an independent predictor for any late cardiac event (OR=2.05, p=0.0002) in general and TLR (odds ratio=2.51, p=0.0001) in particular. CONCLUSIONS. In a large consecutive series of patients treated by elective stent implantation, IDDM patients were at higher risk for in-hospital mortality and subsequent TLR and, as a result, had a significantly lower cardiac event-free survival rate. On the other hand, acute and long-term procedural outcome was found to be similar for non-IDDM compared with nondiabetic patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.