Composite Nonlinear Feedback Control and Stability Analysis of a Grid-Connected Voltage Source Inverter With $LCL$ Filter

Abstract: In this paper, the stability analysis of a gridconnected voltage source inverter with an LCL filter is presented. The Poincaré map is used to analyze the stability of the system from a geometric point of view and provides a better understanding of the system performance. In addition, a composite nonlinear feedback (CNF) control is proposed in order to improve the transient and steady-state performance of the control system. Simulation and experimental analysis verify the validity of the analysis and also show … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
54
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 119 publications
(54 citation statements)
references
References 62 publications
0
54
0
Order By: Relevance
“…To minimize the number of sensors for multi-state feedback control, estimation algorithms should be used. Recently, studies in [76,77] and [78][79][80][81][82][83] separately gave some good examples for slide model control and full-state feedback control. Usually, sampling and control are implemented in digital signal processing (DSP).…”
Section: Implementation Costsmentioning
confidence: 99%
“…To minimize the number of sensors for multi-state feedback control, estimation algorithms should be used. Recently, studies in [76,77] and [78][79][80][81][82][83] separately gave some good examples for slide model control and full-state feedback control. Usually, sampling and control are implemented in digital signal processing (DSP).…”
Section: Implementation Costsmentioning
confidence: 99%
“…Matrix P is calculated with Lyapunov equation (6) with a given positive definite matrix W [17]. Note also that both P, WED nxn •…”
Section: About P and Wmentioning
confidence: 99%
“…In [15] simulations are provided for the case of robust model following problem; whereas [16] discusses Terminal Sliding Mode Control with CNF. Transient response of inverter is improved in [17] using CNF. CNF further was applied in combination with Adaptive Back stepping control in a U tube Steam Generator [18].…”
Section: Introductionmentioning
confidence: 99%
“…In this strategy, two capacitors are placed in parallel at the position of the capacitor in the LCL-filter, and the current between the two capacitors is measured as the feedback signal. In [11], the authors analyzed the generalized stability of a grid-connected VSI with an LCL-filter and proposed a control strategy to improve the transient and steady-state performance called composite nonlinear feedback. In [12][13], the authors analyzed and evaluated the applicability of each part of the overall control in a weak grid with the use of a stability criterion.…”
Section: Introductionmentioning