2018
DOI: 10.3390/app8081309
|View full text |Cite
|
Sign up to set email alerts
|

Computational Fluid Dynamic Accuracy in Mimicking Changes in Blood Hemodynamics in Patients with Acute Type IIIb Aortic Dissection Treated with TEVAR

Abstract: Background: We aimed to verify the accuracy of the Computational Fluid Dynamics (CFD) algorithm for blood flow reconstruction for type IIIb aortic dissection (TBAD) before and after thoracic endovascular aortic repair (TEVAR). Methods: We made 3D models of the aorta and its branches using pre- and post-operative CT data from five patients treated for TBAD. The CFD technique was used to quantify the displacement forces acting on the aortic wall in the areas of endograft, mass flow rate/velocity and wall shear s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
20
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 26 publications
(20 citation statements)
references
References 39 publications
0
20
0
Order By: Relevance
“…: RNN/126/07/KE). Inclusion criteria comprise acute type IIIb aortic dissection that started proximal to the left subclavian artery and involved the renal arteries in each of the analyzed cases [32,33] (Table 1). Table 1.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…: RNN/126/07/KE). Inclusion criteria comprise acute type IIIb aortic dissection that started proximal to the left subclavian artery and involved the renal arteries in each of the analyzed cases [32,33] (Table 1). Table 1.…”
Section: Methodsmentioning
confidence: 99%
“…The average cross-section for the common duct was equal to 1655 32. ± 258.03 mm and 1509.84 ± 244.77 mm for D F and D Hy , respectively.…”
mentioning
confidence: 98%
“…Furthermore, blood density had a set value which enabled us to treat it as incompressible liquid (ρ = const). The blood velocity profiles for each of analyzed patients were obtained from the USG-Doppler examination (GE Vivid 7, GE Healthcare, Fairfield, CT, USA) [ 36 , 37 ]. Moreover, to standardize the 3D models of AAA and stent-grafts reference velocity profiles, flat and sharp, were applied ( Figure 1 ) [ 38 ].…”
Section: Methodsmentioning
confidence: 99%
“…The leachate samples for chromatographic tests were extracted with dichloromethane (10 cm 3 dichloromethane /200 cm 3 sample) by hand shaking for 5 min [28]. After extraction, the organic layer was separated and the samples were extracted again with dichloromethane (10 cm 3 dichloromethane /200 cm 3 sample) [29][30][31]. Due to the formation of emulsions, the separation of the aqueous and organic phase was slow, centrifugation was carried out (2,500 x g, 10 min) to fully separate the phases [32][33][34][35].…”
Section: Methodsmentioning
confidence: 99%