Abstract:A new 3D CFD model has been developed and applied to the hydraulic analysis of three different inlet options for the ITER Central Solenoid. From the point of view of flow repartition among the petals, it appears that shorter, more compact options have even a marginal advantage over a long slit inlet; their hydraulic impedance is larger, but always within the allowable. No overheating associated to low value of the Nb3Sn conductor is predicted for either inlet option.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.