Abstract:The colon capsule endoscopy (CCE) was first introduced in 2007. Currently, the main clinical indications for CCE are completion of incomplete colonoscopy, polyp detection and investigation of inflammatory bowel disease (IBD). Although conventional colonoscopy is the gold standard in bowel cancer screening, incomplete colonoscopy remains a problem as lesions are missed. CCE compares favourably to computer tomography colonography (CTC) in adenoma detection and has therefore been proposed as a method for completing colonoscopy. However the data on CCE remains sparse and current evidence does not show its superiority over CTC or conventional colonoscopy in bowel cancer screening. CCE also seems to show good correlation with conventional colonoscopy when used to evaluate IBD, but there are not many published studies at present. Other significant limitations include the need for aggressive bowel preparation and the labour-intensiveness of CCE reading. Therefore, much further software and hardware development is required to enable CCE to fulfill its potential as a minimally-invasive and reliable method of colonoscopy.