2004
DOI: 10.1148/radiol.2332040277
|View full text |Cite
|
Sign up to set email alerts
|

Computer-aided Detection Performance in Mammographic Examination of Masses: Assessment

Abstract: Performance of CAD systems for mass detection at mammography varies significantly, depending on examination and system used. Actual performance of all systems in clinical environment can be improved.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
82
0
3

Year Published

2007
2007
2020
2020

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 81 publications
(87 citation statements)
references
References 32 publications
2
82
0
3
Order By: Relevance
“…For the queried region in MLO view, the CAD-generated detection and classification scores are 0.52 and 0.40, respectively. Based on CAD analysis, this is an uncued mass-like area (because the detection scores of two regions depicted on CC and MLO view images are smaller than CAD operating cueing threshold of 0.56 [31]) and the probability of this area associated with malignancy is also low based on the comparison of the CBIR-selected similar reference regions. Figure 4 shows and compares two ROC-type performance curves of our interactive CAD system evaluated using two KNN algorithms with the same reference database of 3,600 ROIs and a leave-one-out testing method.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…For the queried region in MLO view, the CAD-generated detection and classification scores are 0.52 and 0.40, respectively. Based on CAD analysis, this is an uncued mass-like area (because the detection scores of two regions depicted on CC and MLO view images are smaller than CAD operating cueing threshold of 0.56 [31]) and the probability of this area associated with malignancy is also low based on the comparison of the CBIR-selected similar reference regions. Figure 4 shows and compares two ROC-type performance curves of our interactive CAD system evaluated using two KNN algorithms with the same reference database of 3,600 ROIs and a leave-one-out testing method.…”
Section: Resultsmentioning
confidence: 99%
“…A conventional CAD scheme [31] is pre-installed in the system, which can preprocess the images of interest stored in the system. For each initially detected suspicious region, this CAD scheme uses a multi-feature-based artificial neural network (ANN) to generate a detection score indicating the likelihood of the region being associated with a truepositive mass.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…However, the lower CAD sensitivity for mass detection and the higher falsepositive rates reduce radiologists' confidence in CAD-cued masses [4]. As a result, although CAD schemes could potentially detect a larger fraction of false-negative cancers depicted as subtle masses [7,8], radiologists frequently discard CAD-cued subtle masses in the clinical practice [9,10]. A recent study reported that using current commercialized CAD systems did not increase cancer detection rate but significantly increase recall (false-positive) rate in the clinical practice [11].…”
Section: Introductionmentioning
confidence: 99%