2019
DOI: 10.1007/978-3-030-12203-4_9
|View full text |Cite
|
Sign up to set email alerts
|

Computer Modeling Application for Analysis of Stress-Strain State of Vibroscreen Feed Elements by Finite Elements Method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
13
0
5

Year Published

2019
2019
2021
2021

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(18 citation statements)
references
References 13 publications
0
13
0
5
Order By: Relevance
“…The phenomenon has been described in reference to the gear pump. Hydrodynamic cavitation occurs in the medium flowing through the internal channels and clearances of the gear pump while the gears (4) are rotating in the body (5) at the pressure difference between the inlet to and the outlet from the pump, which is marked with arrows.…”
Section: -Zone (E)mentioning
confidence: 99%
See 2 more Smart Citations
“…The phenomenon has been described in reference to the gear pump. Hydrodynamic cavitation occurs in the medium flowing through the internal channels and clearances of the gear pump while the gears (4) are rotating in the body (5) at the pressure difference between the inlet to and the outlet from the pump, which is marked with arrows.…”
Section: -Zone (E)mentioning
confidence: 99%
“…The oil flows from the tank (1) to the gear pump (2) which is driven by the electric motor (3).The inlet and outlet pressure in the pump is set by throttling valves (4) and measured with pressure transducers (5). The ultrasonic cavitation in the tank is generated by the oscillator (6) and the cavitator (7).…”
Section: Stand For the Visualization Tests Of The Cavitation Phenomena In And The Gear Pumpmentioning
confidence: 99%
See 1 more Smart Citation
“…Theoretical studies [16][17][18][19][20] and series of experiments showed that the main disadvantage of planetary vibration exciters with an offset rotation axis of the carrier is the inertial runner slipping along the surface of its treadmill. When the optimal variant of its rolling on the treadmill is violated, it leads to a sharp (about ten times) increase in the resistance moment to the rotation of the carrier and the energy intensity of the vibration exciter drive, however, with limited power and the drive motor, it leads to limit the frequency or disruption of [16][17][18][19][20]. The additional energy expended to overcome the sliding friction of the slider goes into heat and implemented to heat the slider and treadmill surface.…”
Section: Analysis Of the Impulse Of The Vibroexciter Driving Force An...mentioning
confidence: 99%
“…To compare the effectiveness of ITEX fiber with existing analogs, SFRC with an anchor fiber 1/50 Hendix and Dramix 3D 80/60BG was also considered. The amount percentage of reinforcement with wire fiber was adopted as 1%, 1.5% and 2%.The composition of the components for fine-grained concrete matrix was selected in accordance with the recommendations of [3,[8][9][10][11][12] and is shown in table 1.…”
Section: Experimental Researchmentioning
confidence: 99%