2005
DOI: 10.1016/j.farmac.2005.03.002
|View full text |Cite
|
Sign up to set email alerts
|

Conductimetric determination of phenylpropanolamine HCl, ranitidine HCl, hyoscyamine HBr and betaine HCl in their pure state and pharmaceutical preparations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0

Year Published

2007
2007
2020
2020

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 18 publications
0
10
0
Order By: Relevance
“…In these cases, the titration curve could be represented by two intersecting lines at the end point. The conductometric technique was used for the determination of many drugs [33,36,39] on using MPA as a titrant; the ion-associates are formed between the studied drugs and MPA as shown in the following equation:…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In these cases, the titration curve could be represented by two intersecting lines at the end point. The conductometric technique was used for the determination of many drugs [33,36,39] on using MPA as a titrant; the ion-associates are formed between the studied drugs and MPA as shown in the following equation:…”
Section: Resultsmentioning
confidence: 99%
“…The titrant was used for quantitative determination of some pharmaceutical compounds applying conductometric, spectrophotometric and potentiometric procedure [33][34][35]. The sharpness of the endpoint is greatly dependent on the solubility of the formed ion-pairs [36]; the conductance data were employed to calculate the solubility products of the considered precipitation reaction. The endpoint was established via an experiential graphical process where the intersection of two straight lines represents the equivalence point.…”
Section: Introductionmentioning
confidence: 99%
“…In order to assure the quality of R . HCl containing pharmaceutical formulations, several methods have been developed for its determination, including high-performance liquid chromatography (HPLC) [1][2][3][4][5][6] , high-performance thin-layer chromatography and scanning densitometry 7 , differential pulse polarography 8 , amperometry 9 , capillary electrophoresis 10 , conductometry 11 , coulometry 12 , voltammetry 13 , potentiometry 14 , fluorimetry 15 , chemiluminescence 16 , AAS 17 . The official method described in the United States Pharmacopeia 18 is based on potentiometric titration of R .…”
Section: Ranitidine N-(2-{[(5-dimethylamino)methyl]-2-furanyl}-methymentioning
confidence: 99%
“…spectrophotometry,[10][11][12] MS,13 NMR14,15 and titration methods [16][17][18]. Potentiometric methods with ion selective electrodes (ISE's) can provide valuable and straightforward means of assaying drugs in complex mixtures, as they make possible the direct (°) Corresponding author; Fax: +20-2-5728843; E-mail address: ayoussef@chem-sci.cu.edu.eg ; hmdyssf@yahoo.com…”
mentioning
confidence: 99%