2012
DOI: 10.1016/j.snb.2011.10.073
|View full text |Cite
|
Sign up to set email alerts
|

Construction of a modified carbon paste electrode for the highly selective simultaneous electrochemical determination of trace amounts of mercury(II) and cadmium(II)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
51
0

Year Published

2013
2013
2015
2015

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 100 publications
(53 citation statements)
references
References 26 publications
2
51
0
Order By: Relevance
“…MWCNT-CPE was modified with a Schiff base. This electrode performed simultaneous detection of Hg(II) and Pb (II) in a number of samples achieving a 0.18 µg/L limit of detection(Afkhami et al 2012b).…”
mentioning
confidence: 99%
“…MWCNT-CPE was modified with a Schiff base. This electrode performed simultaneous detection of Hg(II) and Pb (II) in a number of samples achieving a 0.18 µg/L limit of detection(Afkhami et al 2012b).…”
mentioning
confidence: 99%
“…The main components of the past of these type electrodes are powdered carbon (graphite), mineral (paraffin) oils and the ionophore. Each paste component plays a special role in the paste function [25][26][27][28][29]. Since the sensitivity and selectivity degree of a CPE is greatly related to the carbon paste ingredients, the carbon paste composition influence on the potential responses of the copper ion sensor was studied.…”
Section: Resultsmentioning
confidence: 99%
“…8b shows that the amperometric response is [26]. At higher pH medium, mercury(II) is hydrolysed [49]. Hence, pH 4.0 is selected as medium pH in the subsequent experiments.…”
Section: Supporting Electrolytesmentioning
confidence: 99%
“…The Zn/Al-LDH-MPP/SWCNT CV 1.0 × 10 −7 -1.0 × 10 −3 1.0 × 10 −9 This work 1.0 × 10 −9 -1.0 × 10 −7 SBA-15 nanostructured silica/carbon paste electrode DPASV 2.0 × 10 −6 -1.0 × 10 −5 4.7 × 10 −7 [36] SWCNT-PhSH-modified gold electrode SWASV 5.0 × 10 −9 -9 × 10 −8 3.0 × 10 −9 [45] Nitro benzoyldiphenyl methylene phosphorane/carbon paste electrode SWASV -4.1 × 10 −8 [49] Chitosan/carbon nanotubes paste electrode ASV 6.7 × 10 −9 -8.3 × 10 −8 2.4 × 10 −9 [51] BMIM·BF 4 /MWCNTs ISE 1.0 × 10 −4 -5.0 × 10 −9 2.5 × 10 −9 [52] Bismuth-film/carbon paste electrode SWASV 2.0 × 10 −8 -9 × 10 −8 2.5 × 10 −7 [53] Fluorescent carbon nanoparticles Fluorescent sensing 5 × 10 −8 -1 × 10 −10 2.3 × 10 −8 [54] Single-labelled fluorescent oligonucleotide probe PhSH thiophenol, CV cyclic voltammetry, SWASV square wave anodic stripping voltammetry, DPASV differential pulse anodic stripping voltammetry, ASV anodic stripping voltammetry, ISE ion selective electrode, BMIM·BF4 1-n-butyl-3-methylimidazolium tetrafluoroborate, LOD limit of detection The repeatability measurement of the developed electrode was employed by repeatedly examining the voltammetric response of a single electrode in five different 1 × 10 −3 M Hg 2+ at optimum condition. The RSD obtained for the measurement was 0.61 %.…”
Section: Reproducibility and Repeatability Of Electrodementioning
confidence: 99%