2023
DOI: 10.1101/2023.06.09.544221
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Content-enriched fluorescence lifetime fluctuation spectroscopy to study bio-molecular condensate formation

Abstract: Quantitative fluorescence microscopy is experiencing an important revolution thanks to single-photon array detectors. These detectors provide users with so far inaccessible specimen information: The distribution of the specimen's fluorescence emission at single-photon level and high spatiotemporal sampling. In laser-scanning microscopy, this photon-resolved measurement has enabled robust fluorescence lifetime imaging at sub-diffraction spatial resolution, thus opening new perspectives for structural and functi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(6 citation statements)
references
References 53 publications
0
6
0
Order By: Relevance
“…Fluorescence Correlation Spectroscopy (FCS) measurements were performed as described in (36, 70). Cells were plated and FUS expression was induced as previously described; before starting the acquisition, culture medium was replaced with FluoroBriteTM DMEM (Thermo Fisher, A1896701) supplemented with 10% FBS, and sodium arsenite was added at a final concentration of 0.5 mM for the “stressed” samples.…”
Section: Methodsmentioning
confidence: 99%
“…Fluorescence Correlation Spectroscopy (FCS) measurements were performed as described in (36, 70). Cells were plated and FUS expression was induced as previously described; before starting the acquisition, culture medium was replaced with FluoroBriteTM DMEM (Thermo Fisher, A1896701) supplemented with 10% FBS, and sodium arsenite was added at a final concentration of 0.5 mM for the “stressed” samples.…”
Section: Methodsmentioning
confidence: 99%
“…To perform the FCS measurements, we used a custom laser-scanning microscope equipped with a 5x5 SPAD array detector described by Perego et al 30 .…”
Section: Methodsmentioning
confidence: 99%
“…4d). We also employed a variation of conventional fluorescence correlation spectroscopy, utilizing a single-photon avalanche diode (SPAD) array detector 29,30 . This innovative approach enables comprehensive studies of molecular mobility within living cells.…”
Section: Mettl3 Chemical Inhibition Relieves Fus-containing Sgmentioning
confidence: 99%
See 2 more Smart Citations