Continuous aperture dose calculation and optimization for volumetric modulated arc therapy

Abstract: Although VMAT delivery features continuous gantry rotation and leaf motion, dose calculation is often performed under the dual assumption of discrete apertures changing instantaneously from one discrete angle to the next. In this work, the validity of these two approximations is determined, as well as their impact on the quality of optimized plans. Further, an accurate method of fluence calculation is derived which does not use the discrete aperture approximation, but instead calculates the fluence as the mult… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
58
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 15 publications
(60 citation statements)
references
References 14 publications
2
58
0
Order By: Relevance
“…So long as the control points are spaced by no more that around 2°, this approach is accurate . However, when the apertures are small and the MLC is able to move with a considerable speed, the fluence calculated by this method is inadequate to model the actually delivered fluence . One means of overcoming this inadequacy is to use more closely spaced control points.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…So long as the control points are spaced by no more that around 2°, this approach is accurate . However, when the apertures are small and the MLC is able to move with a considerable speed, the fluence calculated by this method is inadequate to model the actually delivered fluence . One means of overcoming this inadequacy is to use more closely spaced control points.…”
Section: Discussionmentioning
confidence: 99%
“…An alternative method of calculating effective fluence between control points is described by Bedford and can be used with more coarsely spaced control points to provide an accurate dose during optimization. A mathematical means of performing the same calculation is also described by Christiansen et al These methods use the beam orientations of the discrete control points but use the fluence of the moving aperture as it moves between control points. The present study takes the most accurate representation of what is actually delivered to be the optimized plan with segments at 5° intervals recalculated with interpolated segments at 1° intervals and with the method of Christiansen et al or Bedford used between these interpolated segments.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations