Continuous-flow chemiluminescence determination of some corticosteroids

Abstract: A continuous-flow method for the determination of cortisone, hydrocortisone, prednisolone and methylprednisolone in the range 0.100-1.00 pg ml-1 and of dexamethasone and betamethasone in the range 0.500-5.00 pg ml-1 is described. The procedure is based on the action of each corticosteroid as a sensitiser on the chemiluminescent oxidation of sulphite by cerium(lV). The analysis is automated, requires no sample pre-treatment and samples can be analysed at a rate of 40 per hour with a relative error of <6%. The m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
16
0

Year Published

1996
1996
2016
2016

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 51 publications
(16 citation statements)
references
References 11 publications
0
16
0
Order By: Relevance
“…The influences of different acidic media on the CL intensity were studied ( Table 1). The results showed the sulfuric acid was the optimum medium, the same with the CL system involving Ce(IV) or MnO 4 − [26,27,[34][35][36]. Furthermore, the effect of H 2 SO 4 concentration was studied (Fig.…”
Section: Effect Of Acidic Media On the CL Intensitymentioning
confidence: 99%
“…The influences of different acidic media on the CL intensity were studied ( Table 1). The results showed the sulfuric acid was the optimum medium, the same with the CL system involving Ce(IV) or MnO 4 − [26,27,[34][35][36]. Furthermore, the effect of H 2 SO 4 concentration was studied (Fig.…”
Section: Effect Of Acidic Media On the CL Intensitymentioning
confidence: 99%
“…[51][52][53] The emission has been attributed to the formation of excited sulfur dioxide molecules which radiate during de-excitation. [54] The aim of the present work is to develop a sensitive and accurate flow injection CL method for the determination of enalapril maleate and atenolol in pharmaceutical preparations and biological fluids.…”
Section: Introductionmentioning
confidence: 99%
“…The sensitising effect of corticosteroids on the chemoluminogenic reaction between sulfite and cerium(IV) was exploited for their flow-injection (FIA) determination in pharmaceutical formulations. 52,53 A luminol chemiluminescence determination for the same purpose is also described. 54…”
Section: ·6 Chemiluminometrymentioning
confidence: 99%