2021
DOI: 10.3390/rs13132633
|View full text |Cite
|
Sign up to set email alerts
|

Continuous Sensing of Water Temperature in a Reservoir with Grid Inversion Method Based on Acoustic Tomography System

Abstract: The continuous sensing of water parameters is of great importance to the study of dynamic processes in the ocean, coastal areas, and inland waters. Conventional fixed-point and ship-based observing systems cannot provide sufficient sampling of rapidly varying processes, especially for small-scale phenomena. Acoustic tomography can achieve the sensing of water parameter variations over time by continuously using sound wave propagation information. A multi-station acoustic tomography experiment was carried out i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 26 publications
0
8
0
Order By: Relevance
“…Based on the results of direct acoustic path travel time and temperature profile [23], the distance between the two stations was calculated. More details and settings have been provided in [21].…”
Section: Experimental Settingsmentioning
confidence: 99%
See 2 more Smart Citations
“…Based on the results of direct acoustic path travel time and temperature profile [23], the distance between the two stations was calculated. More details and settings have been provided in [21].…”
Section: Experimental Settingsmentioning
confidence: 99%
“…In the process of multi-front identification [21], after two stations are correlated, the peaks with higher SNR were distinguished and identified. The cross-correlation results and multi-peak identifications of S2-S3 during the experiment are stacked in Figure 5.…”
Section: Multi-peak Identificationmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, in order to achieve optimal combustion, as well as safe and efficient operation of the boiler, it is necessary to conduct real-time and accurate monitoring of the temperature distribution inside the boiler [ 1 , 2 , 3 , 4 , 5 ]. The change of atmosphere and ocean has an important impact on the climate and human survival activities, and these changes are also reflected in the change of temperature distribution to a certain extent [ 6 , 7 , 8 , 9 ]. Therefore, the monitoring of temperature distribution in the atmosphere and ocean is not only of great practical significance, but also has broad prospects for development.…”
Section: Introductionmentioning
confidence: 99%
“…Signal resampling is performed to get correlation of received acoustic data. The vertical layer-averaged flow current results between moving station and moored station are inversed with 2D grid method (Huang et al, 2021;Xu et al, 2021;Xu et al, 2022). 3D flow current field is also reconstructed.…”
mentioning