2014
DOI: 10.1007/s00330-014-3510-5
|View full text |Cite
|
Sign up to set email alerts
|

Contrast agent and radiation dose reduction in abdominal CT by a combination of low tube voltage and advanced image reconstruction algorithms

Abstract: ObjectivesTo assess image quality in abdominal CT at low tube voltage combined with two types of iterative reconstruction (IR) at four reduced contrast agent dose levels.MethodsMinipigs were scanned with standard 320 mg I/mL contrast concentration at 120 kVp, and with reduced formulations of 120, 170, 220 and 270 mg I/mL at 80 kVp with IR. Image quality was assessed by CT value, dose normalized contrast and signal to noise ratio (CNRD and SNRD) in the arterial and venous phases. Qualitative analysis was includ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
40
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7
2

Relationship

3
6

Authors

Journals

citations
Cited by 58 publications
(40 citation statements)
references
References 34 publications
0
40
0
Order By: Relevance
“…Intravenous administration of a nonionic iodinated contrast agent (1 mL/kg of iopromide, Ultravist 370; Bayer Healthcare, Berlin, Germany) at a rate of 2–4 mL/sec was used to visualize the index tumor in all patients, followed by a saline flush of approximately 30- to 40-mL [29, 30]. A bolus-tracking program (Smart-Prep; GE Healthcare) was used to commence diagnostic scans after contrast media injection, which was started 20 seconds after reaching the 100 HU contrast enhancement threshold [29] at the mid-phase of the breath–hold, mimicking shallow breathing under conscious sedation, with three pairs of sterile, passive, fiducial markers placed on the skin of the lower chest [31].…”
Section: Methodsmentioning
confidence: 99%
“…Intravenous administration of a nonionic iodinated contrast agent (1 mL/kg of iopromide, Ultravist 370; Bayer Healthcare, Berlin, Germany) at a rate of 2–4 mL/sec was used to visualize the index tumor in all patients, followed by a saline flush of approximately 30- to 40-mL [29, 30]. A bolus-tracking program (Smart-Prep; GE Healthcare) was used to commence diagnostic scans after contrast media injection, which was started 20 seconds after reaching the 100 HU contrast enhancement threshold [29] at the mid-phase of the breath–hold, mimicking shallow breathing under conscious sedation, with three pairs of sterile, passive, fiducial markers placed on the skin of the lower chest [31].…”
Section: Methodsmentioning
confidence: 99%
“…The specific combinations of contrast media iodine concentration and tube voltage (320 mg I/mL at 120 kVp for the standard of care versus 160 and 200 mg I/mL at, respectively, 80 and 100 kVp for the study protocols) used in this study were selected from previous research in abdominal CT [1921]. Based on these experiences and on literature [22], we selected a 60% blending level of ASiR reconstruction for this CCTA study.…”
Section: Introductionmentioning
confidence: 99%
“…Iterative reconstruction (IR) methods are developed to reduce image noise by performing a recursive search for the best estimate, so they can provide a similar image quality at higher noise levels compared with FBP. Consequently, applying IR techniques is considered to be one of the strategies for reducing radiation dose in CT . However, these dose reduction strategies would affect the image performance of CT in terms of contrast, spatial resolution, and noise pattern, and thus may impact the CAC scores.…”
Section: Introductionmentioning
confidence: 99%