Control and Design of Seven-Level Cascaded Multilevel Converter for Transformerless Large-Scale Photovoltaic Integration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 25 publications
0
5
0
Order By: Relevance
“…A three-phase, 3.3 kV, 1.48 MW, and 50 Hz power frequency grid-connected solar PV system is prominently investigated in this work, as given in [37]. The main block diagram of the CHB configuration of the grid-connected PV system is shown in Figure 1a.…”
Section: System Descriptionmentioning
confidence: 99%
See 1 more Smart Citation
“…A three-phase, 3.3 kV, 1.48 MW, and 50 Hz power frequency grid-connected solar PV system is prominently investigated in this work, as given in [37]. The main block diagram of the CHB configuration of the grid-connected PV system is shown in Figure 1a.…”
Section: System Descriptionmentioning
confidence: 99%
“…The main task is to simulate the performance of this 1.48 MW three-phase PV-fed power grid using Nlevel H-bridge inverters. The total number of levels in the cascaded MLI has a value of (2 × number of H − bridge per phase + 1) [37]. For instance, a seven-level inverter con-tains nine H-bridges, so three H-bridges per phase, which are fed by the independent PV array.…”
Section: System Descriptionmentioning
confidence: 99%
“…The system is designed for 3.3 kV, 1.48 MW, and 50 Hz frequency grid. The designing of the parameter is done as given in [12] and Table 1 demonstrates the system specifications. The modulating technique is switches grid‐tied system in a single‐stage that is, without a boost converter.…”
Section: Configuration Of 9‐level Chb Convertermentioning
confidence: 99%
“…The modulating technique is switches grid‐tied system in a single‐stage that is, without a boost converter. The control scheme comprises of improved perturb and observation algorithm for maximum power extraction and decoupled current control with synchronous reference frame (SRF) based phase locked loop (PLL) for voltage source converter (VSC) control as given in [12]. The switching table for the converter is shown in Table 2.…”
Section: Configuration Of 9‐level Chb Convertermentioning
confidence: 99%
See 1 more Smart Citation