2018
DOI: 10.30941/cestems.2018.00032
|View full text |Cite
|
Sign up to set email alerts
|

Control of multiple power inverters for more electronics power systems: A review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
12
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(13 citation statements)
references
References 0 publications
0
12
0
1
Order By: Relevance
“…Uninterruptible Power Supplies (UPS) are used to feed a wide range of electrical loads: from low-power applications (such as domestic computers and networks) to high-power applications of several Megawatt (such as data centers and medical facilities). Over the years, with the emergence of high-power, more important and sensitive critical loads, two main reasons have motivated the connection of UPS systems in parallel: power capacity expansion and improved redundancy [1][2][3].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Uninterruptible Power Supplies (UPS) are used to feed a wide range of electrical loads: from low-power applications (such as domestic computers and networks) to high-power applications of several Megawatt (such as data centers and medical facilities). Over the years, with the emergence of high-power, more important and sensitive critical loads, two main reasons have motivated the connection of UPS systems in parallel: power capacity expansion and improved redundancy [1][2][3].…”
Section: Introductionmentioning
confidence: 99%
“…Control strategies that ensure equal load current distribution between paralleled UPS systems have been proposed in the literature. According to [1,2], these strategies can be divided into two distinct groups, depending on the presence of intercommunication between the paralleled UPS controllers (Figure 1). If the controllers of each UPS share information, the control scheme is defined as active load-sharing scheme.…”
Section: Introductionmentioning
confidence: 99%
“…В зависимости от ряда факторов, таких как взаимного расположения точек подключения включенных в параллель ПП к распределительной сети, закона управления полупроводниковыми ключами, разбросов электрических параметров элементов ПП и других, между параллельно включенными ПП появляются циркуляционные токи, негативно влияющие на КПД системы. Существует ряд способов снижения циркуляционных токов [14]. При этом достаточно эффективным решением, приводящим к снижению циркуляционных токов, является выравнивание мгновенных напряжений на включенных параллельно выходах ПП.…”
Section: Introductionunclassified
“…These converters exist in different implementations such as renewable energy integration, custom power devices, industrial and home appliances in different power ranges [1,2]. In order to convert dc power into ac power, traditional inverters cause high switching losses, electromagnetic interferences and high total harmonic distortion (THD) [3][4][5]. An alternative solution is the utilization of multilevel inverter to minimize the disadvantages of conventional inverters [6].…”
Section: Introductionmentioning
confidence: 99%